2019
DOI: 10.3390/metabo10010008
|View full text |Cite
|
Sign up to set email alerts
|

A Perspective and Framework for Developing Sample Type Specific Databases for LC/MS-Based Clinical Metabolomics

Abstract: Metabolomics has the potential to greatly impact biomedical research in areas such as biomarker discovery and understanding molecular mechanisms of disease. However, compound identification (ID) remains a major challenge in liquid chromatography mass spectrometry-based metabolomics. This is partly due to a lack of specificity in metabolomics databases. Though impressive in depth and breadth, the sheer magnitude of currently available databases is in part what makes them ineffective for many metabolomics studie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 58 publications
0
16
0
Order By: Relevance
“…The table contains the exact mass, chemical formula and peak area of compounds if the expected adducts and isotopologues co-occurred at r 2 > 0.7. For the most abundant compounds, we confirmed the annotation by standards and therefore achieved the annotation level 1 (Sumner et al, 2007;Reisdorph et al, 2020). For other compounds, the annotation was putative and achieved using MS/MS spectra, when available, matched by METABOSCAPE to the libraries HMDB (http://www.…”
Section: Data Processing and Compound Identificationmentioning
confidence: 54%
See 1 more Smart Citation
“…The table contains the exact mass, chemical formula and peak area of compounds if the expected adducts and isotopologues co-occurred at r 2 > 0.7. For the most abundant compounds, we confirmed the annotation by standards and therefore achieved the annotation level 1 (Sumner et al, 2007;Reisdorph et al, 2020). For other compounds, the annotation was putative and achieved using MS/MS spectra, when available, matched by METABOSCAPE to the libraries HMDB (http://www.…”
Section: Data Processing and Compound Identificationmentioning
confidence: 54%
“…The table contains the exact mass, chemical formula and peak area of compounds if the expected adducts and isotopologues co‐occurred at r 2 > 0.7. For the most abundant compounds, we confirmed the annotation by standards and therefore achieved the annotation level 1 (Sumner et al ., 2007; Reisdorph et al ., 2020). For other compounds, the annotation was putative and achieved using MS/MS spectra, when available, matched by M etaboscape to the libraries HMDB (http://www.hmdb.ca/) (Wishart et al ., 2009), GNPS (Global Natural Product Social Molecular Networking) (https://gnps.ucsd.edu/ProteoSAFe/static/gnps-splash.jsp), M oNa (Mass Bank of North America), Vaniya/Fiehn Natural Products Library; Fiehn HILIC; R eSpect (http://spectra.psc.riken.jp) (Sawada et al ., 2012); LC‐MS/MS Spectra (https://mona.fiehnlab.ucdavis.edu/downloads).…”
Section: Methodsmentioning
confidence: 99%
“…[54] We also used the freely accessible AntiBase [40] (AB) 2017 and the Dictionary of Natural Products (http://dnp.chemnetbase.com/faces/chemical/Chemi-calSearch.xhtml; accessed Nov 16, 2020) for molecular formula searches as previously described, [59] which implies different degrees of confidence for the obtained annotations. [60] Cytoscape v3.8.2 was used to visualize the data as a network comprising nodes and edges, wherein each node represents a parent ion and its color reflects the sample (see caption Figure 2) from which the MS/MS file was obtained. [54,61] NMR spectroscopy: NMR spectra were recorded on a Bruker AVANCE III 600 spectrometer operating at a proton frequency of 600.05 MHz and a 13 C frequency of 150.88 MHz.…”
Section: Molecular Networking and Automated Uhplc-hr Ms/msguided Dere...mentioning
confidence: 99%
“…Over recent years a range of different strategies allowing us to apply this idea also in metabolomics has been proposed or implemented. 18 , 144 147 While their actual application is still scarce, they definitely pose a step toward increased reliability of annotations. Another point, which needs to be considered in this regard is the nature of reference spectra used for spectral matching.…”
Section: Nontargeted Data Analysis—increasing Quality By Multiple Linmentioning
confidence: 99%