2017
DOI: 10.1088/1681-7575/aa71db
|View full text |Cite
|
Sign up to set email alerts
|

A permanent magnet system for Kibble balances

Abstract: Note that the electrical power UI is proportional to the Planck constant h via electrical quantum standards [12], and therefore the test mass m can be linked and in the future it can be traced to the Planck constant by a Kibble balance. Currently equation (3) is used for determining the Planck constant, but in the future it will be employed for realizing the mass unit, i.e. the kilogram, in a revised international system of units [13].Two measurement phases are generally separated during the operation of a Kib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
47
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 22 publications
(48 citation statements)
references
References 25 publications
(46 reference statements)
1
47
0
Order By: Relevance
“…As described in Fig. 1 d, experiments at the BIPM prove that this additional magnet field does, in fact, exist 46 , 47 . Hence, the parameter introduced in Eq.…”
Section: Introductionmentioning
confidence: 55%
“…As described in Fig. 1 d, experiments at the BIPM prove that this additional magnet field does, in fact, exist 46 , 47 . Hence, the parameter introduced in Eq.…”
Section: Introductionmentioning
confidence: 55%
“…Comparison of the profile obtained by simulation and measurement. The results in (a) are performed on the BIPM magnet system [18]. The theoretical Br curve is the magnetic flux density distribution along the vertical direction, with a mean radius 126 mm.…”
Section: Discussionmentioning
confidence: 99%
“…Br is the magnetic profile averaged over the coil, for the BIPM system a height of 20 mm. The experimental result is taken from a voltage-velocity ratio measurement, presented in [18]. (b) is based on the NIST-4 magnet system [20].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In fact, the present experimental results, despite their conspicuous five-time uncertainty lowering, still do not support the firm continuity of the units' magnitudes. On the other hand, the CODATA 2017 analysis has been unable to take into account some more recent findings, e.g., on the BIPM Kibble balance [7][8][9], about possible systematic effects.…”
Section: "Exactness" Of the Stipulated Datamentioning
confidence: 99%