2021
DOI: 10.1016/j.apacoust.2020.107656
|View full text |Cite
|
Sign up to set email alerts
|

A parametric study of the acoustic properties of thermal cladding systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
17
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(18 citation statements)
references
References 7 publications
0
17
0
1
Order By: Relevance
“…Some basic material properties of the weatherproof layer, such as thickness and density, are also required. A previous calculation procedure [34] is revised to align the input parameters that contribute to the calculated sound insulation improvement at high and low frequencies, i.e. to give a single resonance frequency that describes both the spring-mass resonance behaviour and the structure-borne transmission through the combined thermal interlayer and wall mounting system.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Some basic material properties of the weatherproof layer, such as thickness and density, are also required. A previous calculation procedure [34] is revised to align the input parameters that contribute to the calculated sound insulation improvement at high and low frequencies, i.e. to give a single resonance frequency that describes both the spring-mass resonance behaviour and the structure-borne transmission through the combined thermal interlayer and wall mounting system.…”
Section: Methodsmentioning
confidence: 99%
“…The latter may increase the measured sound insulation in the laboratory, where flanking transmission is excluded from the receiving room, and this energy is then lost to the laboratory construction. The effect of these conditions is assessed in sections 7.2 and 7.3; they may in part contribute to the unexpectedly high influence of the base wall construction on the sound insulation improvement of thermal insulation systems observed in laboratory measurements [34]. Finally, the standard error of the inputs is discussed in section 7.4 and the conclusions are presented in section 8.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Für Außenwandausführungen mit Wärmedämm-Verbundsystemen gibt es derzeit für die Bemessung des Schallschutzes methodisch, und bedingt durch zu wenig allgemein zugänglichen Daten, nur grobe Abschätzungs-möglichkeiten (ÖNORM B 8115-4, EN ISO 12354-3 und EN ISO 12354-1) [4,5,6], wenn nicht explizit Messergebnisse aus normgemäßen Messungen der Schalldämmung im Prüfstand des jeweils auszuführenden Wandaufbaus zur Verfügung stehen. Detailliertere Methoden stellen u. a. Weber in [7] und Churchill in [8] für mineralische Grundwände vor, an denen WDVS auch hauptsächlich zur Anwendung kommen. Generell ist dessen Anwendung jedoch nicht auf eine massive, mineralische Bauweise beschränkt, sondern mittlerweile auch im Holzrahmenbau als Zusatzdämmung zu jener zwischen den Ständern bzw.…”
Section: Prognose Der Schalldämmung Von Außenwänden Mit Wärmedämm-ver...unclassified