2018
DOI: 10.1111/trf.14975
|View full text |Cite
|
Sign up to set email alerts
|

A paired trial comparing mononuclear cell collection in two machines for further inactivation through an inline or offline extracorporeal photopheresis procedure

Abstract: BACKGROUND Extracorporeal photopheresis (ECP) is an effective treatment. However, protocols differ widely, and some questions, such as the number of cells to be collected or the number of ECP treatment days per treatment cycle, are still unsolved. The aim of this study was to compare a multistep (offline) (Spectra Optia and Macogenic G2) against an integrated (inline) ECP system (Therakos Cellex system) with respect to mononuclear cell (MNC) collection. STUDY DESIGN AND METHODS The number and quality parameter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

7
26
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(33 citation statements)
references
References 11 publications
7
26
0
Order By: Relevance
“…We observed results aligned with previously reported experiences according to FE and %CC methods: 6.6, 7.4, 6.8 FE for lymphocytes, monocytes, and MNCs, respectively; 19.5, 21.4, 21.0 %CC for lymphocytes, monocytes, and MNCs, respectively (see Table ). We used these methods to compare our data with previously published data even if, in our opinion and confirmed by other authors, these methods are simple but largely influenced by differences in patient characteristics (total blood volume) and by real processed blood volume.…”
Section: Discussionsupporting
confidence: 91%
See 3 more Smart Citations
“…We observed results aligned with previously reported experiences according to FE and %CC methods: 6.6, 7.4, 6.8 FE for lymphocytes, monocytes, and MNCs, respectively; 19.5, 21.4, 21.0 %CC for lymphocytes, monocytes, and MNCs, respectively (see Table ). We used these methods to compare our data with previously published data even if, in our opinion and confirmed by other authors, these methods are simple but largely influenced by differences in patient characteristics (total blood volume) and by real processed blood volume.…”
Section: Discussionsupporting
confidence: 91%
“…In literature, non‐standard measurement methods were used to assess CellEx collection efficiency: fold enrichment (FE) and % captured cells (%CC) …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The upper limit of the processed volume is restricted to 2,000 mL. The inline system collected more granulocytes, as also shown by other authors [23, 24]. Recent findings indicate a promoting role of neutrophils at GvHD onset [25]; however, there is a lack of data on whether apoptotic neutrophils might have any effect in this regard.…”
Section: Discussionsupporting
confidence: 53%