2017
DOI: 10.1016/j.jmbbm.2017.06.017
|View full text |Cite
|
Sign up to set email alerts
|

A numerical-experimental protocol to characterize corneal tissue with an application to predict astigmatic keratotomy surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 33 publications
0
11
0
Order By: Relevance
“…Figure 7 shows the relationship between the corrected D and IOP a under various IOP conditions, with the actual IOP values inside being assumed to be 7.5, 15, 22.5, and 45 mmHg. The curve corresponding to the low IOP value (7.5 mmHg) demonstrates a nearly constant IOP a in these models, indicating the rigidity of the structural system providing a considerably greater opposing force than the force obtained from the actual IOP 14 . By contrast, a high IOP could bend the peripheral cornea outwards and flatten the central cornea, resulting in a low IOP a upon applanation.…”
Section: Resultsmentioning
confidence: 80%
See 2 more Smart Citations
“…Figure 7 shows the relationship between the corrected D and IOP a under various IOP conditions, with the actual IOP values inside being assumed to be 7.5, 15, 22.5, and 45 mmHg. The curve corresponding to the low IOP value (7.5 mmHg) demonstrates a nearly constant IOP a in these models, indicating the rigidity of the structural system providing a considerably greater opposing force than the force obtained from the actual IOP 14 . By contrast, a high IOP could bend the peripheral cornea outwards and flatten the central cornea, resulting in a low IOP a upon applanation.…”
Section: Resultsmentioning
confidence: 80%
“…Thus, the stress is transferred to the minor axis and increases the values as illustrated in Figure S1c . Upon applanation, the hoop stress, , in the central cornea decreased because the applanation force bent the central cornea inward, thus compressing the top of the central cornea 14 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As previously reported [13,21], the material behavior of the cornea was defined by a Demiray strain energy function [22] to account for its nonlinear stress/strain relationship;…”
Section: Geometrical and Mechanical Descriptionmentioning
confidence: 99%
“…The wavefront error of the optical system was calculated using an in-house ray tracing algorithm 34 and fitted using Zernike polynomials 35 to calculate the SE, 36 where (µm) is the Zernike coefficient corresponding to the defocus and r 0 (mm) is the radius of the exit pupil of the optical system.…”
Section: Methodsmentioning
confidence: 99%