2013
DOI: 10.1016/j.solener.2013.01.016
|View full text |Cite
|
Sign up to set email alerts
|

A numerical and experimental analysis of the air vent management and heat storage characteristics of a trombe wall

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 73 publications
(21 citation statements)
references
References 11 publications
0
20
0
1
Order By: Relevance
“…The dimensions of the inlet and outlet openings are increased by changing the width of the channel, while increasing the distance between the wall and the glazing also increases the ventilation rate [22]. Liu and others [29] have experimentally and numerically determined that the optimum time to open the ventilation ducts on the Trombe wall is 2-3 hours after sunrise, while the optimal closing time is 1h before sunset. Trombe wall reaches the maximum value of the capacity of the heat accumulation at 16h, while the minimum value is recorded at about 7-8 o'clock in the morning.…”
Section: Influence Of Ventilation Openings and Ventilationmentioning
confidence: 99%
“…The dimensions of the inlet and outlet openings are increased by changing the width of the channel, while increasing the distance between the wall and the glazing also increases the ventilation rate [22]. Liu and others [29] have experimentally and numerically determined that the optimum time to open the ventilation ducts on the Trombe wall is 2-3 hours after sunrise, while the optimal closing time is 1h before sunset. Trombe wall reaches the maximum value of the capacity of the heat accumulation at 16h, while the minimum value is recorded at about 7-8 o'clock in the morning.…”
Section: Influence Of Ventilation Openings and Ventilationmentioning
confidence: 99%
“…heat storage characteristics [22], integrating Photo Voltaic system (PV) with Trombe walls [23][24][25], cost analysis of PV Trombe walls [26] and the application of phase change materials (PCM) in Trombe walls [27]. Researchers endeavored to discover the capability of Trombe walls in reducing the building energy consumption.…”
Section: Effects Of Trombe Walls On Bice Performancementioning
confidence: 99%
“…Studies conducted on this area are essentially about Trombe walls with ventilation openings in the massive wall. As an example of the studies already developed addressing this issue, an optimization research on the opening and closing model of the Trombe wall was conducted using experimental research and numerical calculation [30]. The optimum time to open and close the air vents was analysed.…”
Section: Introductionmentioning