2019
DOI: 10.1038/s41598-019-42910-7
|View full text |Cite
|
Sign up to set email alerts
|

A novel wireless brain stimulation device for long-term use in freely moving mice

Abstract: Deep brain stimulation (DBS) has been used in clinical settings for many years despite a paucity of knowledge related to the anatomical and functional substrates that lead to benefits and/or side-effects in various disease contexts. In order to maximize the potential of this approach in humans, a better understanding of its mechanisms of action is absolutely necessary. However, the existing micro-stimulators available for pre-clinical models, are limited by the lack of relevant small size devices. This absence… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Its great advantage towards DBSsystems currently used in rodent studies is that it is fully implantable. External or partly implanted stimulation systems require single housing of animals or even specialized cages to minimize the chance of system damage [30,31]. Animals in this study could be housed in groups in standard cages, allowing for natural behaviors such as grooming, playing and other social activities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Its great advantage towards DBSsystems currently used in rodent studies is that it is fully implantable. External or partly implanted stimulation systems require single housing of animals or even specialized cages to minimize the chance of system damage [30,31]. Animals in this study could be housed in groups in standard cages, allowing for natural behaviors such as grooming, playing and other social activities.…”
Section: Discussionmentioning
confidence: 99%
“…However, most of these studies applied only acute stimulation lasting for minutes to hours in animals that were anaesthetized or restrained by cables to external stimulators [24][25][26][27][28]. Some studies investigated longer-term stimulation using systems that were fixed on the animals' heads or combining implanted and external parts [29][30][31]. In contrast, DBS in patients is applied continuously over years through a fully implanted system.…”
Section: Introductionmentioning
confidence: 99%
“…[ 39 ] However, externally wired implants frustrate freely moving animals, causing continuous irritation and constraints. [ 40 ]…”
Section: Problems and Challenges Of Flexible Neural Implantsmentioning
confidence: 99%
“…No matter how small electronics can be made, one of the major components of an implant which cannot be scaled easily to mouse proportions is the battery. In fact, up to 80% of the volume of clinical implants is taken up by the battery (Amar et al, 2015 ). As energy storage devices, batteries have certain structural and functional components that do not scale well, resulting in significantly lower stored energy per volume as battery sizes are reduced.…”
Section: Technical Challengesmentioning
confidence: 99%