2018
DOI: 10.1016/j.jbiomech.2018.04.009
|View full text |Cite
|
Sign up to set email alerts
|

A novel validation and calibration method for motion capture systems based on micro-triangulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 9 publications
0
9
0
1
Order By: Relevance
“…A similar static wand length check test is proposed, in order to verify the effect of different calibration procedures on performance [ 22 ]. Another proposal to check the absolute accuracy over a 4 × 2.5 × 3 m 3 volume is through a high-precision 3D scanner used for engineering surveying problems [ 23 ]. In [ 24 ], the authors used a ThorLabs LTS300 linear motion capture device in order to evaluate the accuracy of an optical system composed of 42 cameras in a capture volume of 135 m 3 .…”
Section: Introductionmentioning
confidence: 99%
“…A similar static wand length check test is proposed, in order to verify the effect of different calibration procedures on performance [ 22 ]. Another proposal to check the absolute accuracy over a 4 × 2.5 × 3 m 3 volume is through a high-precision 3D scanner used for engineering surveying problems [ 23 ]. In [ 24 ], the authors used a ThorLabs LTS300 linear motion capture device in order to evaluate the accuracy of an optical system composed of 42 cameras in a capture volume of 135 m 3 .…”
Section: Introductionmentioning
confidence: 99%
“…Instant graphical output is provided, including joint angles [31]. OptiTrack is a widely used motion capture system and considered as one of the most accurate [23,24]. These two systems can be regarded as gold standard markerbased systems; they are installed in movement analysis laboratories for the purposes of gait analysis, musculoskeletal research and animation.…”
Section: Validation Of Microsoft Kinect Azure Camera With Xsens Mvn A...mentioning
confidence: 99%
“…Although the previous Kinect version had acceptable applicability in motion analysis [18][19][20], the Kinect Azure system provides higher accuracy [21,22] and is technically comparable to those of standard motion capture systems, OptiTrack or MVN Xsens. [23][24][25][26]. The aim of the current study was to design a reliable assessment method of the single-leg squat (SLS) test with a second generation Kinect Azure 3D camera.…”
Section: Introductionmentioning
confidence: 99%
“…A key consideration is marker visibility and in this study the optical volume is set up in a configuration so that at least three markers are visible at any point in time [25]. Nagymate et al introduced a novel micro-triangulation-based validation and calibration method for motion capture systems, supporting the volume setup and calibration used in this study [26]. There are several other optical tracking systems such as the one used by Gaspar et al, who introduced an infraredoptical tracking system designed for large scale immersive Virtual Environments or Augmented Reality [27].…”
Section: Related Workmentioning
confidence: 99%