2015
DOI: 10.1109/tps.2015.2416517
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Vacuum Interrupter Contact Design for Improved High Current Interruption Performance Based on a Double-TMF Arc Control System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…In addition, analysis of the arcing traces has shown that the arc behaviour seems to be strongly affected by the temperature distribution on the contact surface as well. Many other teams have also performed in‐depth research on the operation characteristics of the rotary‐based electrodes for vacuum circuit breakers and it could be concluded that sufficient arc rotation along the electrode edge could reduce the electrode erosion caused by the arc and the interruption performance of the vacuum circuit breaker can be improved using this kind of electrodes [14‐‐18]. Nevertheless, it has to be noted that the existing studies have been carried out on vacuum circuit breakers of which the operating mechanism is quite different compared with the PTGS developed in the present work although the principle of the electrode design is similar.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, analysis of the arcing traces has shown that the arc behaviour seems to be strongly affected by the temperature distribution on the contact surface as well. Many other teams have also performed in‐depth research on the operation characteristics of the rotary‐based electrodes for vacuum circuit breakers and it could be concluded that sufficient arc rotation along the electrode edge could reduce the electrode erosion caused by the arc and the interruption performance of the vacuum circuit breaker can be improved using this kind of electrodes [14‐‐18]. Nevertheless, it has to be noted that the existing studies have been carried out on vacuum circuit breakers of which the operating mechanism is quite different compared with the PTGS developed in the present work although the principle of the electrode design is similar.…”
Section: Introductionmentioning
confidence: 99%
“…In the pioneering works [4][5][6], the two different contact shapes were suggested. Corresponding principles are used in the modern contact systems in vacuum interrupters and give inspiration for improved contact geometries [7]. The choice of contact design depends on the electrical and thermal load in a certain application.…”
Section: Introductionmentioning
confidence: 99%
“…In the present study, the influence of the arc ignition position on local surface temperature of the anode and vapor density after current zero crossing was investigated in a model vacuum interrupter using the above-mentioned optical diagnostics under realistic operation conditions. Figure 1 presents the experimental setup, comprising a model vacuum interrupter (vacuum chamber 1 with pneumatic drive 2), a high-current generator (visible in the background of Figure 1), as well as electrical and optical diagnostics (3)(4)(5)(6)(7)(8).…”
Section: Introductionmentioning
confidence: 99%