2020 IEEE Industry Applications Society Annual Meeting 2020
DOI: 10.1109/ias44978.2020.9334766
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Three-Phase Transformerless Cascaded Multilevel Inverter Topology for Grid-connected Solar PV Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…Number of inductors in the proposed inverter and the inverter in Reference 19 is four, while it is six in the inverters in References 15,16,20–22, which is the most among the inverters in Table 2. Number of inductors in the inverters in References 8,10,12,14,17,18,28 is three, while it is two in the inverter in Reference 29, which is the least among the inverters in Table 2. There is no capacitor in the inverters in References 8,15,17,18 because of no output capacitors in the grid‐connected inverters.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Number of inductors in the proposed inverter and the inverter in Reference 19 is four, while it is six in the inverters in References 15,16,20–22, which is the most among the inverters in Table 2. Number of inductors in the inverters in References 8,10,12,14,17,18,28 is three, while it is two in the inverter in Reference 29, which is the least among the inverters in Table 2. There is no capacitor in the inverters in References 8,15,17,18 because of no output capacitors in the grid‐connected inverters.…”
Section: Resultsmentioning
confidence: 99%
“…The CMLC in the three‐level neutral point clamped (NPC) three‐phase inverter can be reduced by selecting the damping resistor in a modified LCL filter 16 . A cascaded three‐phase grid‐connected inverter was also presented to reduce the CMLC 17 . Nevertheless, there are 18 switches in the inverter in Reference 17, which increases complexity and cost of the inverter.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The extracted VE primary grid cells have an irregular geometric structure, forming a one-to-one correspondence with the primary river network of the lake basin. The grid coding form is consistent with the coding scheme of the primary river network of the lake basin, so as to inherit its topological relationship and facilitate the interactive query and retrieval between the MLG and the river network [15][16].…”
Section: Primary Grid Division and Coding Of Vementioning
confidence: 99%
“…Some topologies were presented with reduction in the number of switches in symmetrical and asymmetrical configuration to achieve more levels in the output waveform 4‐9 . The grid‐connected applications for feeding real power and reactive power via the photovoltaic system in addition to the mitigation of harmonics were discussed using multilevel inverters 10‐13 . To suppress the harmonics produced by the multilevel inverter, many modulation schemes were introduced in the past few years.…”
Section: Introductionmentioning
confidence: 99%