2017
DOI: 10.1242/jeb.150235
|View full text |Cite
|
Sign up to set email alerts
|

A novel technique for the precise measurement of CO2 production rate in small aquatic organisms as validated on Aeshnid dragonfly nymphs

Abstract: The present study describes and validates a novel yet simple system for simultaneous in vivo measurements of rates of aquatic CO 2 production (Ṁ CO2 ) and oxygen consumption (Ṁ O2 ), thus allowing the calculation of respiratory exchange ratios (RER). Diffusion of CO 2 from the aquatic phase into a gas phase, across a hollow fibre membrane, enabled aquatic Ṁ CO2 measurements with a highprecision infrared gas CO 2 analyser. Ṁ O2 was measured with a P O2 optode using a stop-flow approach. Injections of known amou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
11
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 12 publications
(13 reference statements)
1
11
0
Order By: Relevance
“…This approach allowed us to quantify how much food the group ate, and thus we estimated the individual feed intake by dividing the total ingested food mass (g) by three. Immediately after feeding stopped, one fish was randomly captured and transferred to a modified glass scintillation vial (22.5 ml), which was part of the novel respirometry system developed by Harter et al (2017). Fasting fish (N=6) were treated identically to feeding fish (N=6), with the same feeding process being simulated, but with no food added to the water.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…This approach allowed us to quantify how much food the group ate, and thus we estimated the individual feed intake by dividing the total ingested food mass (g) by three. Immediately after feeding stopped, one fish was randomly captured and transferred to a modified glass scintillation vial (22.5 ml), which was part of the novel respirometry system developed by Harter et al (2017). Fasting fish (N=6) were treated identically to feeding fish (N=6), with the same feeding process being simulated, but with no food added to the water.…”
Section: Methodsmentioning
confidence: 99%
“…The respirometer (see detailed description and diagrams in Harter et al, 2017) allows simultaneous measurements of ṀC O2 and ṀO 2 , and water sampling for measurements of ṀN in small aquatic organisms. The novel aspect of this apparatus is the use of a hollow fibre membrane (HFM) as the interface between the aqueous phase and a gas phase, providing a large ratio of gas exchange surface area to system volume.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations