2005
DOI: 10.1109/tdei.2005.1511099
|View full text |Cite
|
Sign up to set email alerts
|

A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
41
0
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 109 publications
(42 citation statements)
references
References 5 publications
0
41
0
1
Order By: Relevance
“…For example the speed of propagation in cross linked polyethylene cables (XLPE) is approximately 170m/μs and in gas insulated systems 300m/μs. The ultra wideband detection (UWD) for the measurement of the true shape of a PD pulse has been successfully applied for many years [e.g 52,53]. The separation technique consisting of two components based on time-domain measurements has been proposed in [54].…”
Section: Impact Of Harmonics On Pd Imagesmentioning
confidence: 99%
“…For example the speed of propagation in cross linked polyethylene cables (XLPE) is approximately 170m/μs and in gas insulated systems 300m/μs. The ultra wideband detection (UWD) for the measurement of the true shape of a PD pulse has been successfully applied for many years [e.g 52,53]. The separation technique consisting of two components based on time-domain measurements has been proposed in [54].…”
Section: Impact Of Harmonics On Pd Imagesmentioning
confidence: 99%
“…This is especially important in the case of using this technique with the machine in operation. Following this trend, the analysis of the waveform of the pulse PD is also used for separating partial discharges from electrical noise and even to classify different PD sources (Okubo & Hayakawa, 2005;Cavallini, Montanari, Contin & Pulletti, 2003;Robles, Martinez-Tarifa, Rojas-Moreno & Sanz-Feito 2009).…”
Section: Introductionmentioning
confidence: 99%
“…Firstly, with regard to the PD phenomenon, Section 2 presents the detailed observation results of the PD current of the discharge in gas up to a high frequency band exceeding 10 GHz [15], as well as the study results of the insulation characteristics where micro-defects are present inside the epoxy insulator [16], the detectability of the UHF method with respect to the length of harmful particles inside GIS [17], and both experimental and numerical approaches on propagation phenomena of PD signal in GIS [18]. Subsequently, with regard to further refinement of the diagnostic technique and the calibration and verification method, Section 3 describes a new less uncertain and inexpensive UHF sensor calibration system using a conical antenna [19,20] and a more advanced UHF diagnostic technology whereby the influence of the shape and structures of GIS on PD signal propagation is taken into consideration [21,22], as well as a UHF measurement system sensitivity verification method on the site using a network analyzer [23] to substitute the CIGRE method [13], and the novel technique for PD and breakdown investigation based on current pulse waveform analysis [24].…”
Section: Introductionmentioning
confidence: 99%