The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2017
DOI: 10.3390/s17030457
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording

Abstract: Non-invasive fetal electrocardiograms (FECGs) are an alternative method to standard means of fetal monitoring which permit long-term continual monitoring. However, in abdominal recording, the FECG amplitude is weak in the temporal domain and overlaps with the maternal electrocardiogram (MECG) in the spectral domain. Research in the area of non-invasive separations of FECG from abdominal electrocardiograms (AECGs) is in its infancy and several studies are currently focusing on this area. An adaptive noise cance… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 52 publications
(28 citation statements)
references
References 37 publications
0
27
0
Order By: Relevance
“…Tables 1 , 2 show the calculated values of these parameters for the analyzed records. For the detection of the fQRS complexes, we used an extended version of the Pan and Tompkins algorithm (Pan and Tompkins, 1985 ); and the accuracy of the fECG estimation was evaluated by a beat-to-beat comparison of the extracted fQRS complexes by means of the ICA or PCA methods and the reference fQRS complexes detected in the reference fECG signal acquired by the FSE (Zhang et al, 2017 ). …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Tables 1 , 2 show the calculated values of these parameters for the analyzed records. For the detection of the fQRS complexes, we used an extended version of the Pan and Tompkins algorithm (Pan and Tompkins, 1985 ); and the accuracy of the fECG estimation was evaluated by a beat-to-beat comparison of the extracted fQRS complexes by means of the ICA or PCA methods and the reference fQRS complexes detected in the reference fECG signal acquired by the FSE (Zhang et al, 2017 ). …”
Section: Resultsmentioning
confidence: 99%
“…Techniques utilizing a multi-channel signal source include multiple and single-source methods. Single-channel signal source methods are based on for example Wavelet Transform (WT), Karvounis et al ( 2004 ), Datian and Xuemei ( 1996 ), Hassanpour and Parsaei ( 2007 ), Bsoul ( 2015 ), Ivanushkina et al ( 2014 ), Abburi and Chandrasekhara Sastry ( 2012 ), Bensafia et al ( 2017 ), Castillo et al ( 2013 ), Correlation Techniques De Araujo et al ( 2005 ), Averaging Techniques (AT) Hon and Lee ( 1963 ), Hon and Lee ( 1964 ), Template Subtraction Tsui et al ( 2017 ), Singular Value Decomposition (SVD) Kanjilal et al ( 1997 ), Adaptive Noise Canceler (ANC) Zhang et al ( 2017 ), and so on.…”
Section: State Of the Artmentioning
confidence: 99%
“…Similarly, the second pair of the traditional Ag/AgCl gel electrodes (described in Section III , Part C) was used to quantify the amplitude reduction of the ECG signals alongside the co-located proposed electrodes. The R-wave peak in each cardiac cycle was detected according to the method in described [42] , [43] .…”
Section: Measurementsmentioning
confidence: 99%
“…At present, fetal ECG extraction algorithms mainly include adaptive filtering [ 4 , 5 ], wavelet analysis [ 6 ], matched filtering [ 7 ], blind source separation [ 8 ], independent component analysis (ICA) [ 9 ], neural network [ 10 , 11 ], and singular value decomposition (SVD) [ 12 ]. Among these methods, ICA can separate the source signals from the mixed signals under the assumption that the source signals are statistically independent of each other, without needing any information regarding the source signals or the mixed matrix.…”
Section: Introductionmentioning
confidence: 99%