2015 IEEE Transportation Electrification Conference and Expo (ITEC) 2015
DOI: 10.1109/itec.2015.7165744
|View full text |Cite
|
Sign up to set email alerts
|

A novel SVPWM overmodulation technique for three-level NPC VSI

Abstract: This paper proposes a simple space vector pulse width modulation (SVPWM) scheme for operating a three-phase three-level neutral-point clamped (NPC) voltage source inverter (VSI) at higher modulation indexes, including overmodulation region. Generally, the overmodulation techniques for SVPWM inverter need to store lots of data in the controller beforehand, which produces a huge memory while the control resolution is not perfect. Based on the study of existing overmodulation techniques published in literatures, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 7 publications
(11 reference statements)
0
4
0
Order By: Relevance
“…Generally, the OVM scheme is essential in electrical drive applications, if the drive is required to operate at extended speed including the field-weakening region and with higher torque and power characteristics [234], [235]. Hence the researchers tread in this field to give the significant performance of the MLI in OVM [158], [159].However, the mathematical complexity for achieving OVM is difficult. The CMV elimination in OVM is performed in [160] - [162].…”
Section: B Over Modulation Regionmentioning
confidence: 99%
See 1 more Smart Citation
“…Generally, the OVM scheme is essential in electrical drive applications, if the drive is required to operate at extended speed including the field-weakening region and with higher torque and power characteristics [234], [235]. Hence the researchers tread in this field to give the significant performance of the MLI in OVM [158], [159].However, the mathematical complexity for achieving OVM is difficult. The CMV elimination in OVM is performed in [160] - [162].…”
Section: B Over Modulation Regionmentioning
confidence: 99%
“…But, when the modulation index greater than 0.907, both circular and hexagonal trajectory path is considered. This region is called as over modulation region [158], [159]. In OVM region, the Partial Elimination and Full Elimination of CMV can be done as studied in [160], [161].…”
Section: Open End Winding Five Phase Inverter: Figure 64 Five Phase Open End Winding Topologymentioning
confidence: 99%
“…In [15], three-level voltage source inverters (VSI) were investigated and were simulated implementing both single mode and dual mode overmodulation strategies [15].…”
Section: Introductionmentioning
confidence: 99%
“…In addition to circuit solutions related to the implementation of a high number of output voltage levels of inverters [25,26], there are algorithmic methods to improve the sinusoidality of the output voltage. One such method is the implementation of the overmodulation [27] and waveform optimum [28] mode.…”
Section: Introductionmentioning
confidence: 99%