2019 International Power System Conference (PSC) 2019
DOI: 10.1109/psc49016.2019.9081496
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Strategy for Optimal Battery Sizing Based on MG Frequency Security Criterion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 22 publications
0
10
0
Order By: Relevance
“…Some hardening strategies such as vegetation management and upgrading of network poles are applied to distribution system resilience enhancement. Scheduling of energy storage units [16], [17] and use of mobile emergency resources [18] are the solutions to increase resilience in the operation of distribution networks. Load restoration-based methods are another purpose of increasing resilience that has been used in [19].…”
Section: Nomenclaturementioning
confidence: 99%
“…Some hardening strategies such as vegetation management and upgrading of network poles are applied to distribution system resilience enhancement. Scheduling of energy storage units [16], [17] and use of mobile emergency resources [18] are the solutions to increase resilience in the operation of distribution networks. Load restoration-based methods are another purpose of increasing resilience that has been used in [19].…”
Section: Nomenclaturementioning
confidence: 99%
“…Batteries are accepted as one of the most important and efficient ESSs, 4 which are attractive because they are economic, compact, and easy to deploy. In Reference 5, the battery ESS (BESS) is used for frequency control of an MG in islanded mode. The response time of BESSs is in order of milliseconds, in contrast to slow responding DG units such as DEGs, which makes them appropriate for PFC of MG 6 .…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the utilization of PV for PFC becomes efficient as it mostly operates at MPP, and the consumers' discomfort is also avoided as they do not experience long disturbances in residences' light intensity. Proposing to use PVs and SLEDLLs for handling PFC without FTSs in case of failure of SC, its converter or its controller, so that the MG is stabilized even when the SC is not operational. Previous studies like 5,7 have not considered the operational conditions during which the main ESS fails to handle the frequency control. In this paper, the reliable and safe operation of MG is ensured during these conditions using the proposed control scheme. Introducing a novel scheme for fast controlling of TCLs to participate in PFC.…”
Section: Introductionmentioning
confidence: 99%
“…As far as the MG is connected to the main grid, the demand-supply balance is ensured in the MG, and maintains the frequency of the MG within a tight range. However, the MG may suffer from the load-generation unbalance during the islanded operation [1]. An MG with low inertia can experience large frequency deviations [2].…”
mentioning
confidence: 99%
“…An MG with low inertia can experience large frequency deviations [2]. The installation of an ESS that can quickly inject/absorb power is a solution for keeping the supply-demand balance in the autonomous MG [1]. The power and energy densities are two main characteristics of ESS technologies.…”
mentioning
confidence: 99%