2015
DOI: 10.1109/tpel.2015.2482758
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Soft-Switching Battery Charge/Discharge Converter with Zero Voltage Discharge Function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 41 publications
1
11
0
Order By: Relevance
“…However, when L leak =0.1μH<L leak(min) , the zero voltage turning-on cannot be achieved. This is consistent with formula (14). Furthermore, simulation results under the light load condition are given in Fig.…”
Section: (A) and (B) Insupporting
confidence: 88%
See 1 more Smart Citation
“…However, when L leak =0.1μH<L leak(min) , the zero voltage turning-on cannot be achieved. This is consistent with formula (14). Furthermore, simulation results under the light load condition are given in Fig.…”
Section: (A) and (B) Insupporting
confidence: 88%
“…The low voltage side used a push-pull structure and the high voltage side employed a full bridge structure in [14][15]. With the phase-shift control strategy, all of the switches operate under the ZVS condition.…”
Section: Introductionmentioning
confidence: 99%
“…The circuit's volume weight and cost were reduced by utilising the novel modular multilevel converter topologies 9 along with the soft switching approach for charging and discharging of batteries. 10 The overall operation time depends on the controlling pulses applied to the system and the settling time of the DC input voltage in traditional topologies. The trade-off between the settling time and the regulation of DC voltage level is the major issue in the traditional approaches.…”
Section: Discussionmentioning
confidence: 99%
“…The operating modes of DPS, soft‐switching range, quantitative analysis of the reactive power, and the design complexities are the major challenges in the DPS implementation. The circuit's volume weight and cost were reduced by utilising the novel modular multilevel converter topologies along with the soft switching approach for charging and discharging of batteries . The overall operation time depends on the controlling pulses applied to the system and the settling time of the DC input voltage in traditional topologies.…”
Section: Introductionmentioning
confidence: 99%
“…Other advantages include lower RMS current stress of the switches and easily achievable high partial load efficiency [14][15][16][17]. Although the VF dc-dc converters received increased attention in the research and industry during the last decades, further improvements and soft switching possibilities for CF converters continue to be addressed [18][19][20].…”
Section: Introductionmentioning
confidence: 99%