2018
DOI: 10.1155/2018/5027238
|View full text |Cite
|
Sign up to set email alerts
|

A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification

Abstract: Due to recent technical advances in cataract surgeries, there has been a significant improvement in the safety and surgical outcomes of phacoemulsification. However, the corneal endothelium can be damaged during phacoemulsification by multiple factors. Therefore, we used a slit lamp to analyze the fluid dynamics of ophthalmic viscosurgical devices (OVDs) in the anterior chamber during phacoemulsification. In this experimental study, extracted porcine eyes were injected with OVDs stained with fluorescein throug… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 16 publications
(13 reference statements)
0
10
0
Order By: Relevance
“…In ophthalmic surgery, various methods for assessing surgical invasion have been reported [23,24]. We observed the behavior of OVDs during phacoemulsification using the "slit side view" method and fluorescein-stained OVDs, which enabled viewing of the movement of OVDs intraoperatively and the fluid dynamics in the anterior chamber [25]. With the soft-shell technique, the dispersive OVD formed an uneven layer on the surface of the corneal endothelium, where it remained during the phacoemulsification procedure.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In ophthalmic surgery, various methods for assessing surgical invasion have been reported [23,24]. We observed the behavior of OVDs during phacoemulsification using the "slit side view" method and fluorescein-stained OVDs, which enabled viewing of the movement of OVDs intraoperatively and the fluid dynamics in the anterior chamber [25]. With the soft-shell technique, the dispersive OVD formed an uneven layer on the surface of the corneal endothelium, where it remained during the phacoemulsification procedure.…”
Section: Discussionmentioning
confidence: 99%
“…With the soft-shell technique, the dispersive OVD formed an uneven layer on the surface of the corneal endothelium, where it remained during the phacoemulsification procedure. In contrast, the viscoadaptive OVD remained inside the anterior chamber as a lump, and the irrigation solution often flowed between the corneal endothelium and the OVD, leading to the detachment of the OVD [ 25 ]. These mechanisms may have contributed to the larger ECD reduction rate seen in the V group when compared with the S group at 1 week postoperatively.…”
Section: Discussionmentioning
confidence: 99%
“…The extracted porcine eyes used in this experiment were obtained from a local abattoir. Each porcine eye was positioned on an eyeball fixing stand that was attached to a slit lamp microscope (Takagi, Nagano-ken, Japan) [ 15 ]. We, then, inserted an OVD via the side port and created a 2.4 mm incised corneal wound.…”
Section: Methodsmentioning
confidence: 99%
“…We previously reported the usefulness of the slit side view (SSV), which is a method to observe the anterior chamber in a cross-sectional view [ 15 ]. The SSV allows observation of the movement of ophthalmic viscosurgical devices (OVD) and changes in the anterior chamber depth in accordance with the machine settings during surgery [ 15 ]. The purpose of the current study was to evaluate the usefulness of capsular stabilization devices in Zinn's zonular fiber defect model with SSV.…”
Section: Introductionmentioning
confidence: 99%
“…[8][9][10] Ophthalmic researchers have concluded that retention durability is one of the important properties of OVDs during ocular surgery not only in the intraocular space but also on the ocular surface. [9][10][11][12][13] Previously, we have demonstrated that OVD products have their own rheological properties, even if their product specifications are the same value. 14,15) We have considered that rheological properties, which are not estimated so far, might also influence the retention durability of OVDs not only on the corneal surface but also in the eye.…”
Section: Introductionmentioning
confidence: 99%