25th AIAA Aerodynamic Measurement Technology and Ground Testing Conference 2006
DOI: 10.2514/6.2006-3637
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Sensor for Fast Heat Flux Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…Its working principle is based on temperature difference measurements in very thin films using the transverse Seebeck effect (Renk et al 1994;Knauss et al 2009). The advantages of the ALTP sensor arise from the very thin sensing element (down to 10-100 nm), giving bandwidths up to 1 MHz (Renk et al 1994).…”
Section: Measurement Techniquesmentioning
confidence: 99%
“…Its working principle is based on temperature difference measurements in very thin films using the transverse Seebeck effect (Renk et al 1994;Knauss et al 2009). The advantages of the ALTP sensor arise from the very thin sensing element (down to 10-100 nm), giving bandwidths up to 1 MHz (Renk et al 1994).…”
Section: Measurement Techniquesmentioning
confidence: 99%
“…A thermoelectric field is created when a temperature gradient exist over the yttrium-barium-copper-oxide (YBCO) crystal via the transverse Seebec effect. (26) A spectral resolution up to several hundreds of kilohertz's is expected as a result of the small thickness of the crystal (1 µm) and small sensing area. The manufacturer quotes that a 100 kHz frequency response is obtainable with the ALTP sensor.…”
Section: B Test Matrix and Conditionsmentioning
confidence: 99%
“…In the current ALTP probes δ F ≈ 0.6-0.7 mm with an additional 1 mm protection layer (coating), and the bandwidth is restricted to a time constant of about τ ALTP ≈ 1ms. The amplitude-frequency response coefficients of the sensors were measured and showed that Fourier amplitude was reduced to 1/ √ 2 at frequency 500 kHz [20]. To obtain the maximum spatial resolution the active area has been reduced to the minimum possible length × width = 2 mm × 0.4 mm (Fig.…”
Section: System Of Measurement Control and Data Acquisitionmentioning
confidence: 99%
“…[20]. ALTP signal is digitized by PCI-9812 (© ADLINK Technology Inc.) PC data acquisition card with 5 MHz sampling rate and 524288 record lengths for angle of attack α = 0 • , 2 • .…”
Section: System Of Measurement Control and Data Acquisitionmentioning
confidence: 99%