2012
DOI: 10.1016/j.bios.2012.04.036
|View full text |Cite
|
Sign up to set email alerts
|

A novel sensor based on electrochemical polymerization of diglycolic acid for determination of acetaminophen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 21 publications
0
3
0
1
Order By: Relevance
“…The non-carbon nanomaterials used in the electrochemical detection of PCT regroup a wide variety of materials ranging from metals, metal oxides, ceramics and polymers. Table 3 [ [18] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] , [63] , [64] , [65] , [66] , [67] , [68] , [69] , [70] , [71] , [72] , [73] ] lists the PCT sensors based on non-carbon nanostructure modified electrodes reported up to date.…”
Section: Non-carbon Nanomaterials Modified Electrodesmentioning
confidence: 99%
See 1 more Smart Citation
“…The non-carbon nanomaterials used in the electrochemical detection of PCT regroup a wide variety of materials ranging from metals, metal oxides, ceramics and polymers. Table 3 [ [18] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] , [63] , [64] , [65] , [66] , [67] , [68] , [69] , [70] , [71] , [72] , [73] ] lists the PCT sensors based on non-carbon nanostructure modified electrodes reported up to date.…”
Section: Non-carbon Nanomaterials Modified Electrodesmentioning
confidence: 99%
“…The study done by Xu et al. [ 71 ] indicated that the modified electrode possessed excellent performance for the oxidation of PCT. The LOD was 0.0076 μM associated with very good stability, reproducibility and excellent recovery values (99.1%–101.8%) without any interference.…”
Section: Non-carbon Nanomaterials Modified Electrodesmentioning
confidence: 99%
“…Electrochemical polymerization of reactive monomers on electrode surfaces has been widely used in the establishment of functional polymer films, including the protection of metals, , sensors, and electronic devices. , From previous studies, some unsaturated monomers can be electropolymerized during the cathodic process on the surface of a sodium metal anode, and an ultimate soft polymer interphase is formed between the SPE and the metal anode, which can effectively bond the interface composition and guarantee the Li + transport.…”
Section: Introductionmentioning
confidence: 99%
“…。因此,其质量检测十分重 要。电化学法操作简便,检测速度快,具有较高灵敏 度 [2] 。 基于金纳米粒子的对乙酰氨基酚传感器的研究 近年来,采用电化学方法测定 ACOP 的研究取得 了很大进展。Mingqi Li [3] 等制备了 PANI-MWCNTs 复 合材料修饰电极灵敏测定 ACOP 的含量。Fen Xu [4] 等 研制了一种新型的 DA 电聚合膜用来测定 ACOP,大 大提高了灵敏度。王正国 [5] 等将 ACOP 在纳米金/十二 烷基苯磺酸钠修饰电极上的电化学行为进行了研究。 段连生 [6] 等制备了碳纳米管粉末微电极(CNTPME), 研究了 ACOP 在 CNTPME 上的电化学行为。 Gareth P.…”
unclassified