2019
DOI: 10.1016/j.jpba.2019.01.039
|View full text |Cite
|
Sign up to set email alerts
|

A novel reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of imipenem and meropenem in human plasma and its application in TDM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 33 publications
0
28
1
Order By: Relevance
“…On the one hand, this study confirmed degradation of meropenem at -20 • C in human plasma samples. On the other hand, detailed assessment over 1 year showed that degradation was not yet significant after 3-20 days, as suggested by previous studies [7][8][9][10]. Noteworthy, our results stand in contrast to the findings published by Zander et al [11], who reported substantial decreases of meropenem concentration ≥7 days of storage at −20 • C, with minor amounts remaining after 90-180 days, in serum-based test samples.…”
Section: Discussioncontrasting
confidence: 54%
See 2 more Smart Citations
“…On the one hand, this study confirmed degradation of meropenem at -20 • C in human plasma samples. On the other hand, detailed assessment over 1 year showed that degradation was not yet significant after 3-20 days, as suggested by previous studies [7][8][9][10]. Noteworthy, our results stand in contrast to the findings published by Zander et al [11], who reported substantial decreases of meropenem concentration ≥7 days of storage at −20 • C, with minor amounts remaining after 90-180 days, in serum-based test samples.…”
Section: Discussioncontrasting
confidence: 54%
“…This decrease seemed to compensate for higher relative degradation during the first 100 days. Considering all of the above, meropenem seems to be stable in plasma at −20 • C for longer than the suggested 3-20 days [7][8][9][10].…”
Section: Discussionmentioning
confidence: 84%
See 1 more Smart Citation
“…Meropenem serum concentrations were measured using automatic two-dimensional high-performance liquid chromatography (Demeter Instrument Co., Ltd., Hunan, China). The rst-dimensional chromatographic column was an Aston SNCB (4.6 × 50 mm, 5 µm), and the second-dimensional chromatographic column was an Aston SBN (4.6 × 200 mm, 5 µm) 29,30 . There was an excellent linear relationship between peak area and the concentration range of 0.78 to 58.52 μg/mL.…”
Section: Sampling and Assaysmentioning
confidence: 99%
“…Objective function values (OFV) were used to compare the model t. Covariates were retained in the model if the additional covariates were signi cant at a P-value of 0.01 (△OFV > 6.635). VPC was used to evaluate the goodness of t [12,[29][30][31][32].…”
Section: Pharmacokinetic Studymentioning
confidence: 99%