A Novel Real-time Voltage and Frequency Compensation Strategy for Photovoltaic-based Microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
27
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 49 publications
(27 citation statements)
references
References 34 publications
0
27
0
Order By: Relevance
“…There are two options: an open loop active power versus frequency control, with a hysteresis droop curve, or a defined look-up table; or a control droop method over the active power reference, in order to emulate the characteristic of synchronous generators against frequency excursions. All of them have been applied widely for PV microgrids [9,[13][14][15][16][17][18][19][20]. However, these techniques are not able to be applied on USPVPs, because the capacity of one inverter could not be enough to move the grid frequency [21,22].…”
Section: Local Curtailmentmentioning
confidence: 99%
See 2 more Smart Citations
“…There are two options: an open loop active power versus frequency control, with a hysteresis droop curve, or a defined look-up table; or a control droop method over the active power reference, in order to emulate the characteristic of synchronous generators against frequency excursions. All of them have been applied widely for PV microgrids [9,[13][14][15][16][17][18][19][20]. However, these techniques are not able to be applied on USPVPs, because the capacity of one inverter could not be enough to move the grid frequency [21,22].…”
Section: Local Curtailmentmentioning
confidence: 99%
“…[1]. The most popular technology for PV applications is a battery energy storage system (BESS) [13][14][15][16][17][18][19][20][21][22][23][26][27][28][29].…”
Section: Local Curtailmentmentioning
confidence: 99%
See 1 more Smart Citation
“…It is important to clarify that even with a secondary control layer with no communications, a general communication system is needed for other functionalities of the microgrid as coordination of units during black start processes, real-time monitoring or tertiary control layer. However, reduction of the dependence on communications on each control layer represents an improvement on the reliability of the microgrid [22]. With less dependence on communications, the impact of the real-time data transmission over the control objectives is reduced and the security in terms of communication vulnerability risks is improved.…”
Section: Introductionmentioning
confidence: 99%
“…Under the unbalanced condition, the inverter in MG output three unbalance currents, which contain a large percentage of negative sequence currents. The inverter performance would be seriously affected, the potential issues like: unbalance output voltage due to the negative voltage drop across the output impedance and the inverter output power is fluctuant, leading to voltage and frequency fluctuations [11]. The aforementioned issues degrade MG quality dramatically.…”
Section: Introductionmentioning
confidence: 99%