2022
DOI: 10.3390/app12199706
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Radial Artery P-S Curve Model Based on Radial Vibration of Vascular Wall

Abstract: In pulse wave analysis, the changing curve of pulse wave strength with continuous increasing pressure, that is, the P-S (pressure-strength) curve, contains abundant human physiological information, but there is no accurate model to describe the formation mechanism of the curve. Therefore, this paper proposes a modeling method of the radial artery P-S curve based on the radial vibration of the vascular wall. The modeling method includes three parts. Firstly, based on hemodynamics, we proposed the blood motion e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 29 publications
(39 reference statements)
2
2
0
Order By: Relevance
“…This was achieved using bicubic interpolation, which concatenated the pulse wave intensities from each sensor and created a pulse wave intensity mapping surface for cubic interpolation in the X and Y directions. The smooth 3D pulse wave is shown in Figure 5 c. The pulse intensity along the radial artery was stronger than that around, which was consistent with existing studies [ 4 , 14 ]. The 3D pulse wave was more in line with the pulse diagnosis finger feeling of a TCM doctor.…”
Section: Methodssupporting
confidence: 90%
See 2 more Smart Citations
“…This was achieved using bicubic interpolation, which concatenated the pulse wave intensities from each sensor and created a pulse wave intensity mapping surface for cubic interpolation in the X and Y directions. The smooth 3D pulse wave is shown in Figure 5 c. The pulse intensity along the radial artery was stronger than that around, which was consistent with existing studies [ 4 , 14 ]. The 3D pulse wave was more in line with the pulse diagnosis finger feeling of a TCM doctor.…”
Section: Methodssupporting
confidence: 90%
“…The smooth 3D pulse wave is shown in Figure 5c. The pulse intensity along the radial artery was stronger than that around, which was consistent with existing studies [4,14]. The 3D pulse wave was more in line with the pulse diagnosis finger feeling of a TCM doctor.…”
Section: D Pulse Wave and Pulse Width Measurementsupporting
confidence: 90%
See 1 more Smart Citation
“…The best pulse wave band is obtained by extracting the pulse wave at the strongest point of the D-S curve. Since the signal is stable, the optimal pulse wave band is of great significance in the intelligent diagnosis of traditional Chinese medicine, which is also the pulse wave band that this paper mainly deals with [24]. The hard threshold function and soft threshold function's schematic diagrams are shown in Fig.…”
Section: Pulse Wave Signal Preprocessingmentioning
confidence: 99%