2018
DOI: 10.1109/jestpe.2017.2715721
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Power-Voltage Control Strategy for the Grid-Tied Inverter to Raise the Rated Power Injection Level in a Weak Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(34 citation statements)
references
References 34 publications
0
29
0
Order By: Relevance
“…Transforming (16) to the converter dq reference frame (see Appendix B), and rearranging yields (17). Finally, (18) shows the linearised small signal state-space form of (17) [36,37] (see Appendix A):…”
Section: Current Control Loopmentioning
confidence: 99%
See 2 more Smart Citations
“…Transforming (16) to the converter dq reference frame (see Appendix B), and rearranging yields (17). Finally, (18) shows the linearised small signal state-space form of (17) [36,37] (see Appendix A):…”
Section: Current Control Loopmentioning
confidence: 99%
“…The authors proposed an impedance-phase compensation control scheme by increasing the phase margin of the grid-connected inverter. A similar approach was proposed in [17], where a novel power-voltage control strategy was proposed based on voltage feedback control of the voltage across the capacitor of the LCL output filter of the inverter. Reference [17] concluded that the stability of a grid-tied inverter remains unchanged with increasing PLL bandwidth.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the dynamics of VSI is changed into a linear time-invariant (LTI) system in the synchronous rotating reference frame. By means of this, the VSI system can be easily designed and analyzed by using the linear control techniques [12]- [18]. For the standard VCC, since the d-q axes currents have to be in phase with the grid voltage, the phase angle used by the Park transformation has to be extracted from the grid voltages correctly [1].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the converters can conduct active power filtering (APF) for the loads [7][8][9], and conduct power balancing for diesel generator outputs [10,11]. When ac grid fails, the converters can act as uninterruptible power systems (UPS) to supply both dc and ac loads [12,13]. In summary, the multifunction converters can fulfill real-and reactive-power injection, rectification, active power filtering, threephase power balancing and UPS functions.…”
Section: Introductionmentioning
confidence: 99%