2018
DOI: 10.1088/1748-0221/13/01/t01005
|View full text |Cite
|
Sign up to set email alerts
|

A novel PMT test system based on waveform sampling

Abstract: Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8”R5912 and the 20”R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of ch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…19a, where the averaged values now increased to 28.5 % for the HPK PMTs and 30.1 % for NNVT PMTs. The average PDE of the qualified NNVT low-QE PMTs was updated to 27.3 %, and 31.3 % for the qualified NNVT high-QE PMTs respectively 21 , as shown in Fig. 19b.…”
Section: Light System Aging and Pde Correctionmentioning
confidence: 99%
See 1 more Smart Citation
“…19a, where the averaged values now increased to 28.5 % for the HPK PMTs and 30.1 % for NNVT PMTs. The average PDE of the qualified NNVT low-QE PMTs was updated to 27.3 %, and 31.3 % for the qualified NNVT high-QE PMTs respectively 21 , as shown in Fig. 19b.…”
Section: Light System Aging and Pde Correctionmentioning
confidence: 99%
“…Concerning the mechanical safety which is relevant for the large vacuum glass bulbs of PMTs working in pure water at a maximum depth of 44 m, a careful inspection is performed on each PMT to identify any mechanical/structural defects. Furthermore, following many valuable, previously performed studies on different PMT parameters, such as general studies on the large area PMT performance [19][20][21][22][23][24][25], temperature effects [26][27][28][29], and the lifetime of the newly developed MCP-PMT by Northern Night Vision Technology Co. (NNVT) [30][31][32][33], follow-up studies on the DCR as a function of temperature and the long-term stability of the MCP-PMTs are evaluated.…”
Section: Introductionmentioning
confidence: 99%
“…The model of this LT-Dis is N840 from CAEN. Then, a FlashADC (FADC, DT5751) from CAEN was used to sample the waveforms [29].…”
Section: Experimental System 21 Measurement Systemmentioning
confidence: 99%
“…Photomultiplier tubes (PMTs) are extensively utilized in particle physics experiments that require single-photon-sensitive light detection, such as Super-K [1,2], KamLAND [3], SNO [4], IceCube [5], Double Chooz [6], Daya Bay [7], and RENO [8]. The performance and characterization of PMTs have been extensively studied and well-understood [9][10][11][12][13][14][15][16][17][18][19][20][21][22].…”
Section: Introductionmentioning
confidence: 99%