A Novel MRI Tracer-Based Method for Measuring Water Diffusion in the Extracellular Space of the Rat Brain (December2013)

Abstract: We proposed a novel MRI tracer-based method for the determination of water diffusion in the brain extracellular space (ECS). The measuring system was validated in 32 Sprague Dawley rats. The rats were randomly divided into four groups with different injection sites: 1) caudate nucleus (Cn.); 2) thalamus (T.); 3) cortex (Cor.); and 4) substantia nigra (Sn.). The spin-lattice relaxation time of hydrogen nuclei in water molecules were shortened, which presented as high signal on MRI after the injection of gadolin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
52
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 43 publications
(55 citation statements)
references
References 21 publications
3
52
0
Order By: Relevance
“…We found that Vd-max% of the SN was higher in the PD group than that of the other three groups, indicating that harmful substances such as α-syn were retained longer and distributed more widely in the PD model SN, increasing the likelihood of toxicity (Han et al, 2014; Ren et al, 2016). A previous study investigated tracer clearance in the normal rat SN ECS, but did not clearly establish clearance timesor diffusion ranges for the tracer (Han et al, 2014). Our study found that t 1/2 values were increased in the PD group compared to the other three groups, consistent with the above finding regarding Vd-max%.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…We found that Vd-max% of the SN was higher in the PD group than that of the other three groups, indicating that harmful substances such as α-syn were retained longer and distributed more widely in the PD model SN, increasing the likelihood of toxicity (Han et al, 2014; Ren et al, 2016). A previous study investigated tracer clearance in the normal rat SN ECS, but did not clearly establish clearance timesor diffusion ranges for the tracer (Han et al, 2014). Our study found that t 1/2 values were increased in the PD group compared to the other three groups, consistent with the above finding regarding Vd-max%.…”
Section: Discussionmentioning
confidence: 95%
“…Brain images were obtained with a high-resolution T1-weighted 3-dimensional magnetization-prepared rapid-acquisition with gradient echo (T1 3DMP-RAGE) sequence with the parameters specified by Han and Zuo (Han et al, 2014; Zuo et al, 2015). A 2-μl volume of 10 mmol/L Gd-DTPA solution (Magnevist; Bayer Schering Pharma AG, Berlin, Germany) was injected directly into the SN as described above (see Section Surgical Procedure).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…IOI technology measures light signals generated by a fluorescent probe in ECS. Tracer-based MRI method uses magnetic sensitive contrast agents as a probe to tag and track water molecules in ISF 24) .…”
mentioning
confidence: 99%