Eurosensors 2018 2018
DOI: 10.3390/proceedings2130993
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Modular eNose System Based on Commercial MOX Sensors to Detect Low Concentrations of VOCs for Breath Gas Analysis

Abstract: In this work, a new generation of eNose systems particularly suited for exhaled breath gas analysis is presented. The developed analyzer system comprises a compact modular, low volume, temperature controlled sensing chamber explicitly tested for the detection of acetone, isoprene, pentane and isopropanol. The eNose system sensing chamber consists of three compartments, each of which can contain 8 analog Metal Oxide (MOX) sensors or 10 digital MOX sensors. Additional sensors within the digital compartment allow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 7 publications
(12 citation statements)
references
References 8 publications
(9 reference statements)
0
12
0
Order By: Relevance
“…Semiconducting gas sensors are applied to test some of these gases, such as acetone, hydrogen peroxide, volatile sulfur, nitric oxide, and ammonia [ 191 ]. However, the research is being conducted into constructing eNose systems based on commercial MOX sensors to detect low concentrations of VOCs in breath [ 192 ], further improved by temperature modulation, containing 8 analog and 10 digital commercial MOX sensors [ 193 ].…”
Section: Applicationmentioning
confidence: 99%
“…Semiconducting gas sensors are applied to test some of these gases, such as acetone, hydrogen peroxide, volatile sulfur, nitric oxide, and ammonia [ 191 ]. However, the research is being conducted into constructing eNose systems based on commercial MOX sensors to detect low concentrations of VOCs in breath [ 192 ], further improved by temperature modulation, containing 8 analog and 10 digital commercial MOX sensors [ 193 ].…”
Section: Applicationmentioning
confidence: 99%
“…This study is mainly motivated by the difficulty of calibration of eNoses for breath analysis applications, the differences between instruments, the frequent recalibrations needed due to aging and drift and the environmental and other different conditions present in different hospitals which prevents obtaining a unified dataset for deep statistical studies. Another goal in this work, is to present our modular breath analyzer (MBA) platform (shown in Figure 1 ), a new updated version of our modular eNose [ 80 , 81 , 82 ] specifically designed for breath analysis. The previous version of the modular eNose concept was recently presented [ 80 , 81 , 82 ].…”
Section: Introductionmentioning
confidence: 99%
“…Another goal in this work, is to present our modular breath analyzer (MBA) platform (shown in Figure 1 ), a new updated version of our modular eNose [ 80 , 81 , 82 ] specifically designed for breath analysis. The previous version of the modular eNose concept was recently presented [ 80 , 81 , 82 ]. It consisted of a new eNose platform based on a novel modular sensing chamber, where different kinds of chemoresistive sensors can be combined [ 80 , 81 , 82 ].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations