2012
DOI: 10.1016/j.bios.2011.11.021
|View full text |Cite
|
Sign up to set email alerts
|

A novel microfluidic immunoassay system based on electrochemical immunosensors: An application for the detection of NT-proBNP in whole blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(23 citation statements)
references
References 10 publications
0
23
0
Order By: Relevance
“…NT‐proBNP detection was based on changes in hexanocyanoferrate solutions cyclic voltammograms without or with Ag‐Ab reaction. This system constituted the basis for a sandwich‐configuration immunosensor developed by the same group 22 (see Section 2.3. ).…”
Section: Electrochemical Biosensors For Cardiovascular Markersmentioning
confidence: 99%
See 1 more Smart Citation
“…NT‐proBNP detection was based on changes in hexanocyanoferrate solutions cyclic voltammograms without or with Ag‐Ab reaction. This system constituted the basis for a sandwich‐configuration immunosensor developed by the same group 22 (see Section 2.3. ).…”
Section: Electrochemical Biosensors For Cardiovascular Markersmentioning
confidence: 99%
“…Liang et al. 22 recently described an amperometric regeneration‐free immunosensor for the determination of NT‐proBNP combined with a microfluidic system which enabled continuous determination. Avidin‐modified magnetic nanoparticles were incubated in a mixture of biotinylated capture antibody, the sample and a secondary antibody labeled with a Pt and Prussian blue nanomaterial (PPN).…”
Section: Electrochemical Biosensors For Cardiovascular Markersmentioning
confidence: 99%
“…New, simpler, cost-effective methods for BNP detection such as the immunosensors are being tested as candidates for the detection of NTproBNP. They detect NT-proBNP in serum such as the regeneration-free immunosensor with novel Fab fragment monoclonal antibodies that detects NT-proBNP from 0.04 to 2.5 ng/ml with a limit of 0.03 ng/ml (12) or in whole blood such as the combination of a microfluidic system with an immunoassay based on an electrochemical immunosensor with magnetic nanoparticles, biotin-avidin system (BAS) and fragment antigen binding (Fab) antibodies (13) or the electrochemical immunosensor based on the nanostructural gold and carbon nanotubes composite, gold nanochains (AuNCs) and horseradish peroxidase (HRP) complex labeled secondary antibodies (AuNCs-HRP-Ab(2)) (14).…”
Section: Biomarkers Of Myocyte Stress and Apoptosis In Hfmentioning
confidence: 99%
“…Currently, the standard control of the reagent flow is done by intelligent microfluidic systems with micropumps and valves. However, the need for novel, low-resource fabrication and assembly methods for creating disposable detectors leads to the development of alternative microfluidics concepts such as hybrid paper-polymer devices [102], centrifugal micro- [103], and regeneration-free immunosensors [104]. The recent surge in the development of microfluidics systems was fuelled by research advances in polymer science.…”
Section: Microfluidic Systemsmentioning
confidence: 99%