A Novel Method to Read Remotely Resonant Passive Sensors in Biotelemetric Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(17 citation statements)
references
References 9 publications
0
17
0
Order By: Relevance
“…As described previously, besides improvements from using the developed dataprocessing-based readout method from a software perspective, low-noise circuitry and techniques from a hardware perspective should be included to electronically reduce the measurement noise and enhance the SNR in phase-dip frequency detection [31]. Other readout methods have also been explored in different research groups [40]- [42] with the aim of long-range telemetric sensing and are valuable for comparison to the configuration proposed in this work. Moreover, in cases where either the sensor-reader coil coupling or quality factor of the sensor is substantial enough to influence the frequency shift resolution based on (10), some compensation method would be required as part of the final telemetric system.…”
Section: B In Vivo Testmentioning
confidence: 99%
“…As described previously, besides improvements from using the developed dataprocessing-based readout method from a software perspective, low-noise circuitry and techniques from a hardware perspective should be included to electronically reduce the measurement noise and enhance the SNR in phase-dip frequency detection [31]. Other readout methods have also been explored in different research groups [40]- [42] with the aim of long-range telemetric sensing and are valuable for comparison to the configuration proposed in this work. Moreover, in cases where either the sensor-reader coil coupling or quality factor of the sensor is substantial enough to influence the frequency shift resolution based on (10), some compensation method would be required as part of the final telemetric system.…”
Section: B In Vivo Testmentioning
confidence: 99%
“…An inductively coupled passive telemetric system including the effects of parasitic capacitances and leakage fluxes is proposed in [10]. A wireless approach to measure the RLC passive sensors resonance frequency and Q factor is reported in [19] where the developed method is based on simultaneous application of three excitation signals of constant amplitude with different frequencies. All of these focused on the concept based on passive inductive coupling and sensing the change in the capacitance of LC closed loop resonance circuit.…”
Section: Introductionmentioning
confidence: 99%
“…This demanded the need to develop new measurement methods for characterizing the micro coils wirelessly. Previously passive wireless read out using inductive coupling for measuring different physical quantities have been reported frequently [1][2][3][4][5][6]. All of these publications focused on the concept based on inductive coupling and sensing the change in the capacitance of LC closed loop resonance circuit.…”
Section: Introductionmentioning
confidence: 99%