1992
DOI: 10.1016/0952-0600(92)90069-s
|View full text |Cite
|
Sign up to set email alerts
|

A novel method to assess airway function parameters in chronically instrumented, unrestrained guinea-pigs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
67
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(67 citation statements)
references
References 20 publications
0
67
0
Order By: Relevance
“…Via an external saline-filled cannula, the intrapleural balloon catheter was connected to a pressure transducer (TXX-R; Viggo-Spectramed, Bilthoven, The Netherlands), and P pl was continuously measured using an online computer system. By use of a combination of flow measurement with a pneumotachograph implanted inside the trachea and pressure measurement with the intrapleural balloon catheter, it was previously shown that changes in P pl are linearly related to changes in airway resistance and hence can be used as a sensitive index for allergen-and histamineinduced bronchoconstriction (Santing et al, 1992). In this way, airway function can be monitored continuously and repeatedly for prolonged periods of time, whereas the animals are unaware of the measurements being taken.…”
Section: Measurement Of Airway Functionmentioning
confidence: 99%
See 2 more Smart Citations
“…Via an external saline-filled cannula, the intrapleural balloon catheter was connected to a pressure transducer (TXX-R; Viggo-Spectramed, Bilthoven, The Netherlands), and P pl was continuously measured using an online computer system. By use of a combination of flow measurement with a pneumotachograph implanted inside the trachea and pressure measurement with the intrapleural balloon catheter, it was previously shown that changes in P pl are linearly related to changes in airway resistance and hence can be used as a sensitive index for allergen-and histamineinduced bronchoconstriction (Santing et al, 1992). In this way, airway function can be monitored continuously and repeatedly for prolonged periods of time, whereas the animals are unaware of the measurements being taken.…”
Section: Measurement Of Airway Functionmentioning
confidence: 99%
“…These provocations were carried out in a specially designed perspex cage of 9 liters in which the guinea pigs could move freely, as previously described (Santing et al, 1992;Meurs et al, 2006). A DeVilbiss nebulizer (type 646) driven by an airflow of 8 l/min provided the aerosol with an output of 0.33 ml/min.…”
Section: Provocationsmentioning
confidence: 99%
See 1 more Smart Citation
“…All animals were sensitised to ovalbumin (grade III ovalbumin; Sigma Chemical Co., St Louis, MO, USA) at 3 weeks of age as described previously [15]. In order to obtain a shift to IgE-class antibodies, an allergen solution containing 100 mg?mL -1 ovalbumin and 100 mg?mL -1 Al(OH) 3 (J.T.…”
Section: Animalsmentioning
confidence: 99%
“…Airway function was assessed by on-line measurement of pleural pressure (Ppl) under unrestrained conditions as described previously [15]. In brief, a small fluid-filled latex balloon connected to a saline-filled cannula was surgically implanted inside the thoracic cavity.…”
Section: Measurement Of Airway Functionmentioning
confidence: 99%