2013
DOI: 10.2174/1386207311301010007
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Method for High Throughput Lipophilicity Determination by Microscale Shake Flask and Liquid Chromatography Tandem Mass Spectrometry

Abstract: Modern small molecule drug design requires the optimization of not only the binding characteristics of the molecule but also its physicochemical properties for ADMET performance. A key physical property is lipophilicity and medicinal chemists need rapid access to high quality data in order to drive their decision making. Traditionally lipophilicity (log D) measurements are performed with a shake flask method and UV determination. This method suffers from low sensitivity and is not easily converted to a high th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
46
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(46 citation statements)
references
References 24 publications
0
46
0
Order By: Relevance
“…Unfortunately, this compound was inactive in the cell-based assay. We suspect this molecule may be too polar (measured LogD = -0.4 at pH 7.4), 9 to be cellularly permeable. Encouragingly, 2-furyl and 3,4-pyrazole analogs (42 and 43) showed improved KDM5A enzyme inhibition potency relative to 1.…”
mentioning
confidence: 96%
“…Unfortunately, this compound was inactive in the cell-based assay. We suspect this molecule may be too polar (measured LogD = -0.4 at pH 7.4), 9 to be cellularly permeable. Encouragingly, 2-furyl and 3,4-pyrazole analogs (42 and 43) showed improved KDM5A enzyme inhibition potency relative to 1.…”
mentioning
confidence: 96%
“…Distribution coefficient measurements utilized a shake flask approach based on a liquid chromatography–tandem mass spectrometry (LC–MS/MS) technique previously developed for 1-octanol/water distribution coefficient measurements [21]. The approach is described in Section II B, and the procedure is schematically summarized in Figure 2.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…This selection was expanded to include 31 compounds used as internal standards for the previously developed octanol/water assay protocol [21], bringing the total number of compounds for which measurements were performed to 95. These compounds were randomly assigned numerical SAMPL_XXX designations for the SAMPL5 blind challenge.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations