2019
DOI: 10.1016/j.ejmp.2019.04.013
|View full text |Cite
|
Sign up to set email alerts
|

A novel method for EBT3 Gafchromic films read-out at high dose levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 47 publications
0
16
0
Order By: Relevance
“…Although in this work the optimal upper range was found to be ~40 Gy, adopting the methodology reported in Ref. for other film models and more recently by Vaiano et al, the dynamic range may be significantly extended. One version of multichannel film dosimetry as per Micke et al varies the dose values until the corresponding scanned optical density values for various color channels are best matched.…”
Section: Discussionmentioning
confidence: 70%
“…Although in this work the optimal upper range was found to be ~40 Gy, adopting the methodology reported in Ref. for other film models and more recently by Vaiano et al, the dynamic range may be significantly extended. One version of multichannel film dosimetry as per Micke et al varies the dose values until the corresponding scanned optical density values for various color channels are best matched.…”
Section: Discussionmentioning
confidence: 70%
“…To this aim, spectrophotometers have been used for the characterization of several RCF types to different radiation fields [93][94][95]. RCF spectral characterization has also been carried out by means of broadband spectrometers in combination with optical fibers [88,89,96,97]. As an example of this, Figure 6 shows the spectral response of EBT-3 Gafchromic™ film to several doses in the range 0-20 Gy.…”
Section: Densitometers and Spectrometersmentioning
confidence: 99%
“…The spectra of Figure 6 have been acquired by means of an opto-electronic system, of which a full description can be found in [96,97]. For the sake of clarity, its basic operation is summarized here.…”
Section: Densitometers and Spectrometersmentioning
confidence: 99%
“…Gafchromic MD-55 films are regarded as accurate dosimeters, capable of measuring doses with an uncertainty of less than 1% near 6 Gy (Klassen et al, 1997). Gafchromic EBT3 films are very sensitive to radiation and can be used in the range of 0.5 to 100 Gy (Vaiano et al, 2019). These latter films were made of microcrystals of the lithium salt of 10,12-pentacosadiynoic acid (PCDA) dispersed in gelatin (Balakrishnan et al, 2010;Callens et al, 2016).…”
Section: Introductionmentioning
confidence: 99%