2017
DOI: 10.1016/j.nano.2016.08.009
|View full text |Cite
|
Sign up to set email alerts
|

A novel method for dengue virus detection and antibody screening using a graphene-polymer based electrochemical biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
53
0
3

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 112 publications
(56 citation statements)
references
References 36 publications
0
53
0
3
Order By: Relevance
“…albumin, lysozyme [23] and nuclear matrix protein 22 (NMP22) [24]) and even microorganisms (e.g. viruses [25], bacteria [26] and algae [27]) have been used as the imprinting templates. Moreover, molecularly imprinted polymers can be integrated on microfluidic systems for either dielectric or electrochemical sensing of viruses [28] and urinary melatonin [29], respectively.…”
Section: Introductionmentioning
confidence: 99%
“…albumin, lysozyme [23] and nuclear matrix protein 22 (NMP22) [24]) and even microorganisms (e.g. viruses [25], bacteria [26] and algae [27]) have been used as the imprinting templates. Moreover, molecularly imprinted polymers can be integrated on microfluidic systems for either dielectric or electrochemical sensing of viruses [28] and urinary melatonin [29], respectively.…”
Section: Introductionmentioning
confidence: 99%
“…In particular, Dickert and Lieberzelt developed a plethora of platforms (principally based on quartz microbalance) with molecularly imprinted polymers (MIPs) to detect cells [47], bacteria [48], and viruses [49]. In addition, Lieberzelt and his group recently reported some electrochemical applications with MIPs: in 2014 [50], Cu 2+ ions were conductometrically detected down to 0.2 mM by polymerizing N-vinyl-2-pyrrolidone and, in 2016 [51], dengue virus was impedimetrically detected with a 0.12 pfu/mL detection limit by using a graphene oxide-polymer composite. Even the group of Cleij in Maastrischt, which is one of the most active regarding the use of MIPs, developed an impedimetric assay to detect histamine in intestinal fluid patient samples [52].…”
Section: Polymers As the Sensing Elementmentioning
confidence: 99%
“…The composites were prepared by using a previously reported method: acrylamide (AAM), methyl methacrylate (MMA), methacrylic acid (MAA), and n‐vinylpyrrolidone (NVP) were mixed with graphene oxide sheets. In the composites, graphene oxide was used to enhance the polymer conductivity, making it suitable for EIS measurements . The monomers served as sensitive layer building blocks with side‐chain groups covering a range of interactions, which were present on the virus surface and BPA.…”
Section: Figurementioning
confidence: 99%
“…The composites were prepared by using ap reviously reported method: [48] acrylamide (AAM), methyl methacrylate (MMA), methacrylic acid (MAA), and n-vinylpyrrolidone (NVP) were mixed with graphene oxide sheets. In the composites, graphene oxide was used to enhance the polymer conductivity,m aking it suitable for EIS measurements.…”
Section: Mcipsa Nd Mips Eis Gold Electrode Preparationsmentioning
confidence: 99%
See 1 more Smart Citation