2021
DOI: 10.1109/tmi.2020.3044357
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Low-Dose Dual-Energy Imaging Method for a Fast-Rotating Gantry-Type CT Scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 54 publications
(48 reference statements)
0
6
0
Order By: Relevance
“…The innovation of the proposed method compared with previously reported beam-modulated single-scan DECT methods (Lee et al, 2017;Cho et al, 2020;Petrongolo and Zhu, 2018) is mainly three-fold: small primary loss, deep learning-based data restoration scheme and easy manipulation. First of all, the proposed method employs the detector modulation scheme to reduce the dimension of the penumbra area compared with the source-side modulation methods by up to 80%.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The innovation of the proposed method compared with previously reported beam-modulated single-scan DECT methods (Lee et al, 2017;Cho et al, 2020;Petrongolo and Zhu, 2018) is mainly three-fold: small primary loss, deep learning-based data restoration scheme and easy manipulation. First of all, the proposed method employs the detector modulation scheme to reduce the dimension of the penumbra area compared with the source-side modulation methods by up to 80%.…”
Section: Discussionmentioning
confidence: 99%
“…Strips with equal width and spacing are employed in this work to realize uniform modulation frequency across the whole object. In this work, 5-mm strip width is empirically determined to construct the beam modulator, which has a higher modulation frequency and reduced penumbra areas compared to previous beam-modulation works (Petrongolo and Zhu, 2018;Lee et al, 2017;Cho et al, 2020).…”
Section: Implementation Detailsmentioning
confidence: 99%
See 1 more Smart Citation
“…Lee et al, designed a multi‐slit filter and acquired DE‐CBCT data via linear reciprocation motion of the filter 31 . This method was then adopted by Cho et al, for fast‐rotating gantry‐type CT scanner 37 . Petrongolo and Zhu proposed to achieve single‐scan DECT/DE‐CBCT via inserting a stationary primary modulator, 36 which is also promising for simultaneous cone‐beam scatter removal and DE‐CBCT imaging.…”
Section: Introductionmentioning
confidence: 99%
“…31 This method was then adopted by Cho et al, for fast-rotating gantry-type CT scanner. 37 Petrongolo and Zhu proposed to achieve single-scan DECT/DE-CBCT via inserting a stationary primary modulator, 36 which is also promising for simultaneous cone-beam scatter removal and DE-CBCT imaging. All of these methods enabled single-scan DE-CBCT, and achieved satisfied performance in dual-energy imaging and material decomposition.…”
Section: Introductionmentioning
confidence: 99%