2016
DOI: 10.1038/srep28248
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Long-term, Multi-Channel and Non-invasive Electrophysiology Platform for Zebrafish

Abstract: Zebrafish are a popular vertebrate model for human neurological disorders and drug discovery. Although fecundity, breeding convenience, genetic homology and optical transparency have been key advantages, laborious and invasive procedures are required for electrophysiological studies. Using an electrode-integrated microfluidic system, here we demonstrate a novel multichannel electrophysiology unit to record multiple zebrafish. This platform allows spontaneous alignment of zebrafish and maintains, over days, clo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
79
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 64 publications
(84 citation statements)
references
References 41 publications
5
79
0
Order By: Relevance
“…Studies that rely on only one modality are intrinsically limited and cannot capture the full complexity of epileptic activity. Recent developments include multi-electrodes platforms for the parallel LFP recording from multiple larvae [15,17,18,20]. These methods are extremely useful for the screening of antiepileptic drugs, but the presence of a large LFP transient is not sufficient to define an epileptic event.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Studies that rely on only one modality are intrinsically limited and cannot capture the full complexity of epileptic activity. Recent developments include multi-electrodes platforms for the parallel LFP recording from multiple larvae [15,17,18,20]. These methods are extremely useful for the screening of antiepileptic drugs, but the presence of a large LFP transient is not sufficient to define an epileptic event.…”
Section: Discussionmentioning
confidence: 99%
“…Up to now, locomotion represents the main readout of the epileptic phenotype and the pattern and speed of swimming behavior of larvae can indeed be measured using automated locomotion-tracking [14] to provide information on seizure severity and on the outcome of administered drugs. Electrophysiological recordings [9,[15][16][17][18] permit activity monitoring in intact larvae, but the analysis of the electrophysiology data relies mostly on their visual inspection. Moreover, it is often difficult to tell true epileptiform activity apart from physiological events, such as eye and tail movements [18] on account of the high sensibility of the electric signal to muscle activity due to the small dimension of the entire organism.…”
mentioning
confidence: 99%
“…Noise level was measured as 0.35 ± 0.03 mV (n = 18). All scn1lab mutants exhibit some form of spontaneous electrographic seizure activity and no clustering of activity was observed even with prolonged electrophysiology monitoring (see 22 ). Both events were counted using “threshold” and/or “template” detection settings in Clampfit (Molecular Devices; Sunnyvale, CA).…”
Section: Methodsmentioning
confidence: 99%
“…3), we risk missing important phenotypes by not being able to identify more subtle and short-lived abnormalities occurring spontaneously at unpredictable times. This is particularly relevant where seizures may be rare, as compared to long-term monitoring possible with electrophysiological recordings [116], the imaging duration is often limited by data storage, fish maintenance during the recording and bleaching of the fluorescence by the laser.…”
Section: Future Directionsmentioning
confidence: 99%