2022
DOI: 10.1016/j.colsurfa.2022.129484
|View full text |Cite
|
Sign up to set email alerts
|

A novel kaempferol electrochemical sensor based on glass carbon electrode modified by poly (3, 4-ethylenedioxythiophene) decorated with green synthesized MIL-100(Fe)-multi- walled carbon nanotubes composites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 40 publications
0
5
0
Order By: Relevance
“…Among them, MIL-100(Fe) is used as a transition metal MOF, which has two different mesoporous cages (2.5 and 2.9 nm). It has high stability, a rigid zeotype crystal structure, biocompatibility, and a large number of coordinatively unsaturated metal sites [23], which makes it show promising applications in catalysis [24], adsorption and separation [25]. Furthermore, it is used in photocatalytic applications owing to its excellent optical properties [26] and as a carrier for drug delivery applications [27].…”
Section: Introductionmentioning
confidence: 99%
“…Among them, MIL-100(Fe) is used as a transition metal MOF, which has two different mesoporous cages (2.5 and 2.9 nm). It has high stability, a rigid zeotype crystal structure, biocompatibility, and a large number of coordinatively unsaturated metal sites [23], which makes it show promising applications in catalysis [24], adsorption and separation [25]. Furthermore, it is used in photocatalytic applications owing to its excellent optical properties [26] and as a carrier for drug delivery applications [27].…”
Section: Introductionmentioning
confidence: 99%
“…In general, a mixture of H 2 SO 4 (60 mL) and HNO 3 (20 mL), with a volume ratio of 3 to 1, was used to acidify and functionalize MWCNT (1.0 g) (MWCNTs-AO) [ 37 ]. An amount of 20 mg MWCNTs-AO, 1.32 mL PdCl 2 /DES solution (5 mg/mL), and 0.44 mL Ni(NO 3 ) 2 /DES solution (5 mg/mL) were added to 10 mL DES.…”
Section: Methodsmentioning
confidence: 99%
“…The detection of the flavone baicalein in human urine was achieved at a GCE modified by Bi2O3 and CMWCNTs, with an LOD of 2.0 nM in the linear range from 0.01 to 15 µM [85] (Figure 11). The flavonol kaempferol in XinDaKang tablets was detected at an electrochemical sensor based on GCE modified with a nonocomposite consisting of MOF MIL-100(Fe), MWCNTs and PEDOT, and it showed a linear range from 50 to 1950 nM and an LOD of 13.2 nM [118].…”
Section: Flavonoids Determination In Human Biological Fluidsmentioning
confidence: 99%