2021
DOI: 10.1007/s10895-021-02839-5
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Imidazole Bound Schiff Base as Highly Selective “Turn-on” Fluorescence Sensor for Zn2+ and Colorimetric Kit for Co2+

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 43 publications
0
5
0
Order By: Relevance
“…However, a noticeable uorescence enhancement was observed when Zn 2+ or Al 3+ ions were added into the DMSO/H 2 O (9:1, v/v) solution of SHK, respectively. The weak uorescence in free SHK solution was due to the photoinduced electron transfer (PET) process involving lone pairs of electron N atoms, which blocked the radiation of the uorescent group [21][22][23][24][33][34]. The turn-on uorescence responses of SHK towards Zn 2+ and Al 3+ ions were ascribed to the inhibition of the PET process and the promotion of chelation-enhanced uorescence (CHEF) after binding to metal ions [21][22][23][24][33][34].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, a noticeable uorescence enhancement was observed when Zn 2+ or Al 3+ ions were added into the DMSO/H 2 O (9:1, v/v) solution of SHK, respectively. The weak uorescence in free SHK solution was due to the photoinduced electron transfer (PET) process involving lone pairs of electron N atoms, which blocked the radiation of the uorescent group [21][22][23][24][33][34]. The turn-on uorescence responses of SHK towards Zn 2+ and Al 3+ ions were ascribed to the inhibition of the PET process and the promotion of chelation-enhanced uorescence (CHEF) after binding to metal ions [21][22][23][24][33][34].…”
Section: Resultsmentioning
confidence: 99%
“…To determine the stoichiometric ratio of the probe SHK with Zn 2+ , Job-plots of SHK with Zn 2+ were calculated from the continuous variation of the uorescent emission intensity during the titration process [21][22][23][24]. A plot of uorescent intensity attained to a maximum at a molar ratio of ca.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the presence of Zn (II) ions, measurable fluorescence signals were generated at 612 nm, accompanied with bath color enhancement. The sensitivity of the fluorescence method for the determination of Zn (II) ions (6.78 × 10 −9 M) was far lower than the World Health Organization’s drinking water guidelines (7.6 × 10 −5 M), so it could become a practical system for monitoring the concentration of Zn (II) ions in water samples [ 505 ].…”
Section: Imidazole-based Supermolecules As Pathological Probesmentioning
confidence: 99%
“…(m) A reversible naphthalimide-based probe detected Hg (II) ions in a phosphate buffer over a wide pH range (7.0–10.0), which is highly applicable in biological experiments [ 63 ]. (n) Imidazolyl Schiff bases exhibit Zn (II) detection as low as 6.78 × 10 −9 M compared to the recommended sensitivity detection according to the World Health Organization’s drinking water guidelines (7.6 × 10 −5 M) [ 64 ]. (o) Imidazole-based anthracene structure detection limit of Zn (II): 1.0 × 10 −9 M [ 65 ].…”
Section: Introductionmentioning
confidence: 99%