2006
DOI: 10.1016/j.sna.2006.03.015
|View full text |Cite
|
Sign up to set email alerts
|

A novel hysteretic model for magnetorheological fluid dampers and parameter identification using particle swarm optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
186
0
2

Year Published

2008
2008
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 267 publications
(190 citation statements)
references
References 15 publications
2
186
0
2
Order By: Relevance
“…Bouc-Wen model has been used to describe hysteretic behaviour [8] in many mechanical and structural fields, including beam members [9,10], concrete walls [11], seismic isolation devices [12], wood joints [13], magneto-rheological fluid dampers [14,15], to cite some.…”
Section: Cyclic Constitutive Laws For the Flexural And Shear Hingesmentioning
confidence: 99%
“…Bouc-Wen model has been used to describe hysteretic behaviour [8] in many mechanical and structural fields, including beam members [9,10], concrete walls [11], seismic isolation devices [12], wood joints [13], magneto-rheological fluid dampers [14,15], to cite some.…”
Section: Cyclic Constitutive Laws For the Flexural And Shear Hingesmentioning
confidence: 99%
“…Hysteresis in dampers is due to the difference between the accelerating and decelerating paths of the force-velocity curve [10], thus imposing a delay in the changes of internal pressures and ultimately forces. Therefore, we propose the nonlinear MR damping force (F MR ) approximated by a hyperbolic tangential function of the velocity and the displacement of the oscillator based on the papers [11,12]. In terms of mathematical expressions, the model makes use of a hyperbolic tangent function to represent the hysteresis and linear function to represent the viscous behaviour…”
Section: Model Of Magnetorheological Damper (Mrd)mentioning
confidence: 99%
“…Here, counteract the force-offset problem for a single damper, a differential configuration of two identical dampers is used, as described in [13,14]. Accordingly, the damper force generated by j th MR damper is given by Note that according to the proposed differential configuration, the damper displacements are opposite in sign, that is…”
Section: System Descriptionmentioning
confidence: 99%
“…We next consider a ten-storey building model embedded with one pair of identical dampers to be placed on the first storey, with the parameters of the dampers given in [13]. Here, the building model has following structural parameters: Table II for the case no control and with this controller (b).…”
Section: Multi-storey Modelmentioning
confidence: 99%
See 1 more Smart Citation