2004
DOI: 10.1016/s0378-7796(03)00158-5
|View full text |Cite
|
Sign up to set email alerts
|

A novel hysteresis current control for active power filter with constant frequency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
28
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(33 citation statements)
references
References 4 publications
0
28
0
Order By: Relevance
“…Particle swarm optimization (PSO) is a population based stochastic optimization technique developed by Dr. Beernaert and Dr. Kennedy in 1995, inspired by social behaviour of bird flocking or fish schooling's shares many similarities with evolutionary computation techniques such as Genetic Algorithms (GA) [69][70][71][72]. The system is initialized with a population of random solutions and searches for optima by updating generations.…”
Section: Particle Swarm Optimizationmentioning
confidence: 99%
See 1 more Smart Citation
“…Particle swarm optimization (PSO) is a population based stochastic optimization technique developed by Dr. Beernaert and Dr. Kennedy in 1995, inspired by social behaviour of bird flocking or fish schooling's shares many similarities with evolutionary computation techniques such as Genetic Algorithms (GA) [69][70][71][72]. The system is initialized with a population of random solutions and searches for optima by updating generations.…”
Section: Particle Swarm Optimizationmentioning
confidence: 99%
“…It is faster and gets better results in most cases. It also avoids some of the problems GA met [72]. But it has some disadvantages.…”
Section: Particle Swarm Optimizationmentioning
confidence: 99%
“…Among these techniques, the hysteresis band is used very often because of its simplicity of implementation, fast response current and robust structure [13], [14]. Hysteresis band controller is used to track the line current references.…”
Section: Three-level Hysteresis Current Controllermentioning
confidence: 99%
“…One disadvantage is that it is difficult to limit the minimum and maximum switching frequencies in order to have a good tracking of the reference current. Several solutions are known to overcome this limitation but they increase the controller complexity, (Zeng et al, 2004). Additionally, other features should be referred: 1-there is a lack of intercommunication between the individual hysteresis controllers and therefore no strategy to generate zero voltage vectors; 2-it has a tendency to lock into limit cycles of high frequency switching; and 3-it causes the generation of sub-harmonic current components, (Holmes & Lipo, 2003).…”
Section: Current Controllermentioning
confidence: 99%