2005
DOI: 10.1016/j.aca.2005.03.030
|View full text |Cite
|
Sign up to set email alerts
|

A novel homogeneous assay format utilising proximity dependent fluorescence energy transfer between particulate labels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
20
1
1

Year Published

2006
2006
2015
2015

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(24 citation statements)
references
References 12 publications
2
20
1
1
Order By: Relevance
“…[33] An optical FRET-based multiion sensor has been designed by incorporating two independent sensing systems and QDs in submicron spheres. [34] Apart from some bioassays based on ruthenium-or europium-chelate-doped polymer NPs, [35,36] the use of fluorescent polymer NPs for the elaboration of FRET-based sensors or probes is still in its infancy. [1] We have recently shown that ligand-functionalized fluorescent polymer NPs are efficient and selective sensors for cupric ions in water using the quenching of fluorescence by energy transfer from dyes to metal complexes as a transduction signal.…”
Section: Introductionmentioning
confidence: 99%
“…[33] An optical FRET-based multiion sensor has been designed by incorporating two independent sensing systems and QDs in submicron spheres. [34] Apart from some bioassays based on ruthenium-or europium-chelate-doped polymer NPs, [35,36] the use of fluorescent polymer NPs for the elaboration of FRET-based sensors or probes is still in its infancy. [1] We have recently shown that ligand-functionalized fluorescent polymer NPs are efficient and selective sensors for cupric ions in water using the quenching of fluorescence by energy transfer from dyes to metal complexes as a transduction signal.…”
Section: Introductionmentioning
confidence: 99%
“…The limit of detection was slightly better compared with assay using Tb chelates and FRET-based detection [42] and comparable to assay using Eu nanoparticles and FRET-based detection [43]. The obtained limit of detection also enables further development of the PSA assay for clinical applications where a cutoff of 4 ng/ ml is used, and patients with higher concentrations are examined further [44].…”
Section: Homogeneous Psa Assaymentioning
confidence: 74%
“…In the absence of inhibitor, the enzyme cleaves the substrate releasing the quencher, leading to emission of the fluorescent acceptor. Another FRET system has been described in a homogeneous sandwich immunoassay for prostate specific antigen (PSA) using Eu(III) chelate-doped donor NPs and near-infrared fluorescent acceptor microparticles, which were coated with two different PSA antibodies [56].…”
Section: Individual Assaysmentioning
confidence: 99%