2021
DOI: 10.3390/ijerph18116142
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy

Abstract: The aim of this human cadaver study was to assess the accuracy of zygomatic/pterygoid implant placement using custom-made bone-supported laser sintered titanium templates. For this purpose, pre-surgical planning was done on computed tomography scans of each cadaver. Surgical guides were printed using direct metal laser sintering technology. Four zygomatic and two pterygoid implants were inserted in each case using the guided protocol and related tools. Post-operative computed tomography (CT) scans were obtaine… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(18 citation statements)
references
References 43 publications
0
14
0
Order By: Relevance
“…After removing duplicates ( n = 56), 51 articles were screened using title-abstract-keyword reading, leaving 35 reports eligible (substantial agreement, κ = 0.95). After full-text reading and a subsequent search for relevant citations, 14 studies were included in this systematic review [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ] (100% of agreement among the reviewers) ( Figure 1 ). One current retrospective study from Wu included [ 19 ], and other fives studies from the same team (Shanghai Jiaotong University) were excluded due to the same population were collected in Wu’s publication [ 19 ].…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…After removing duplicates ( n = 56), 51 articles were screened using title-abstract-keyword reading, leaving 35 reports eligible (substantial agreement, κ = 0.95). After full-text reading and a subsequent search for relevant citations, 14 studies were included in this systematic review [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ] (100% of agreement among the reviewers) ( Figure 1 ). One current retrospective study from Wu included [ 19 ], and other fives studies from the same team (Shanghai Jiaotong University) were excluded due to the same population were collected in Wu’s publication [ 19 ].…”
Section: Resultsmentioning
confidence: 99%
“…The main characteristics of the included studies are described in Table 1 according to guidance approach, system, number of examinations, ZI characteristics, and conclusions. A total of 14 studies [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ], including one RCT [ 32 ], two retrospective studies [ 15 , 19 ], five prospective studies [ 12 , 13 , 33 , 34 , 37 ], six cadaver studies with one comparative analysis [ 8 , 10 , 11 , 14 , 35 , 36 ], were retrieved from the search. Those reported ZI planned/placed accuracy in 144 patients (77 male and 67 female) and 35 cadavers with total of 511 ZIs (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179); six studies used 35 cadavers with 118 ZIs.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations