2018
DOI: 10.1016/j.aca.2018.08.013
|View full text |Cite
|
Sign up to set email alerts
|

A novel gas sampling introduction interface for fast analysis of volatile organic compounds using radiofrequency pulsed glow discharge time of flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 18 publications
0
7
2
Order By: Relevance
“…The LOD values in the range of 0.5-5 ppb were achieved, which is perspective for the real application of the new approach for a wide range of analytical tasks, including the determination of VOCs in human exhalation. 15,16 When comparing our results with previous studies, 1,3,5 the following aspects may be identified. The combination of several factors related to the nature of the pulsed glow discharge resulted in the combination of two beneficial outcomes for the online detection mode, which are often hard to achieve together.…”
Section: No + + M → No + M +mentioning
confidence: 49%
See 3 more Smart Citations
“…The LOD values in the range of 0.5-5 ppb were achieved, which is perspective for the real application of the new approach for a wide range of analytical tasks, including the determination of VOCs in human exhalation. 15,16 When comparing our results with previous studies, 1,3,5 the following aspects may be identified. The combination of several factors related to the nature of the pulsed glow discharge resulted in the combination of two beneficial outcomes for the online detection mode, which are often hard to achieve together.…”
Section: No + + M → No + M +mentioning
confidence: 49%
“…Contrary to a previous study, 3 we introduced a supplementary argon flow into the discharge cell since the discharge could not be properly initiated without it. The increase of air pressure reduced the sensitivities of the VOCs and increased the intensity of the copper associates, as observed in our previous study.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Fandino et al [ 21 ] used a Grimm cell for the ionization of VOCs with the detection in a time-of-flight mass spectrometer (TOFMS). Radiofrequency (13.6 MHz) packets with a duration of 40–50 µs and packet repetition frequency of 400 Hz were used for the ionization.…”
Section: Introductionmentioning
confidence: 99%