2011
DOI: 10.1016/j.saa.2011.08.006
|View full text |Cite
|
Sign up to set email alerts
|

A novel fluorescent sensor for Cr3+ based on rhodamine-cored poly (amidoamine) dendrimer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…However, the major disadvantages of these methods include the demand for expensive and complex apparatus along with complicated sample pretreatments in these time-consuming processes [25,26]. Over the past several years, fluorescent chemosensors have been developed as useful sensors for various metal ions due to their simplicity, specificity and sensitivity monitoring with a fast response time [27][28][29].…”
Section: Introductionmentioning
confidence: 99%
“…However, the major disadvantages of these methods include the demand for expensive and complex apparatus along with complicated sample pretreatments in these time-consuming processes [25,26]. Over the past several years, fluorescent chemosensors have been developed as useful sensors for various metal ions due to their simplicity, specificity and sensitivity monitoring with a fast response time [27][28][29].…”
Section: Introductionmentioning
confidence: 99%
“…As demonstrated in the mechanism determinations in previous papers, rhodamine‐based chemosensors generally show drastic color changes that are visible to the naked eye, from colorless to purple or pink, because they are structurally transformed into a ring‐opened amide over the spirolactam forms. Following interaction of the probes with target species – such as cations, anions and neutral molecules – or by exposure to external factors such as heat and pressure, broadband amplification could be observed in both the UV‐Vis absorption and fluorescence emission spectra [6,37–49] . The instrumental analyses are verified in detail, which are included in the supplementary electronic information.…”
Section: Resultsmentioning
confidence: 94%
“…Following interaction of the probes with target speciessuch as cations, anions and neutral molecules -or by exposure to external factors such as heat and pressure, broadband amplification could be observed in both the UV-Vis absorption and fluorescence emission spectra. [6,[37][38][39][40][41][42][43][44][45][46][47][48][49] The instrumental analyses are verified in detail, which are included in the supplementary electronic information.…”
Section: Synthesis Of Chemosensorsmentioning
confidence: 99%
“…In this section those papers are presented in which both core and periphery were modified. 22,35,37 In these cases the detection principles were based on using the PET or FRET mechanisms.…”
Section: Modified Pamam-type Dendrons For Sensor Applicationsmentioning
confidence: 99%