2013
DOI: 10.1016/j.bios.2013.04.048
|View full text |Cite
|
Sign up to set email alerts
|

A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
28
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(28 citation statements)
references
References 22 publications
0
28
0
Order By: Relevance
“…AuNPs, which have exceptional quenching ability, have been mostly used in fluorescence quenching immunoassay. The important advantages of these LFAs are the low background signal, high sensitivity and ability to label with multiple biorecognition elements [183].…”
Section: Fluorescent Quenching Materialsmentioning
confidence: 99%
“…AuNPs, which have exceptional quenching ability, have been mostly used in fluorescence quenching immunoassay. The important advantages of these LFAs are the low background signal, high sensitivity and ability to label with multiple biorecognition elements [183].…”
Section: Fluorescent Quenching Materialsmentioning
confidence: 99%
“…The PVC sheet (30 cm  6 cm) was applied as the backing plate, and the NC membrane (2.5 cm wide) was placed on the center of the PVC sheet. FQICS were developed referring to the work reported by Fu et al and Shi et al, 25,29 and performed as following. OVA-QDs complexes were diluted with a suitable amount of 0.01 M, pH 7.4 PBS.…”
Section: Construction Of Fqicsmentioning
confidence: 99%
“…24 However, the uorescent particles have the peculiarity of sticking to the nitrocellulose (NC) membrane, due to their large size and tendency to agglomerate. 25 Futhermore, this kind of ICS with signal "turn off" mode, still suffers from relatively not high sensitivity because of requiring large amount of target analytes to eliminate the signals on the test (T) line. New immune chromatographic strip research efforts are focusing on the development of multi-analyte-residue analysis and the improvement of assay sensitivity.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The porosity of these matrices can make them capable of entrapping and immobilizing fluorescent dyes to sense different explosives. During the past decades, chemical sensors based on fluorescence quenching have been fabricated and studied in many laboratories [22][23][24][25]. To the best of our knowledge, there is no report on fluorescence quenching of rhodamine 6G by 1,3,5-Trinitroperhydro-1,3,5-triazine (RDX) in sol-gel matrix.…”
Section: Introductionmentioning
confidence: 99%