2020
DOI: 10.1109/access.2020.3028224
|View full text |Cite
|
Sign up to set email alerts
|

A Novel FBG-Based Triggering System for Cardiac MR Imaging at 3 Tesla: A Pilot Pre-Clinical Study

Abstract: This first-ever study demonstrates the applicability of a fiber Bragg grating (FBG) system for MR cardiac triggering of cardiovascular magnetic resonance at 3 Tesla. The unique patented system senses body movements caused by cardiac activity using a non-invasive ballistocardiography (BCG) sensor. The pilot research compares a novel FBG-based system with clinically used triggering systems based on electrocardiography (ECG) and pulse oximetry (POX). The pilot pre-clinical study was conducted on 8 subjects at a S… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 67 publications
(77 reference statements)
1
8
0
Order By: Relevance
“…The gained precision and resistance to artifacts from the MR environment promise the successful usability of FBG sensors in synchronization of MRI. That was proved in our previous study published in [55],…”
Section: B Recent Approaches To Mr Triggeringsupporting
confidence: 60%
See 2 more Smart Citations
“…The gained precision and resistance to artifacts from the MR environment promise the successful usability of FBG sensors in synchronization of MRI. That was proved in our previous study published in [55],…”
Section: B Recent Approaches To Mr Triggeringsupporting
confidence: 60%
“…The use of the proposed sensors can lead to higher image sharpness and noise reduction, thus increasing the quality of acquired images. In general, the study provided additional information on the proposed systems, which have been already the objects of our previous papers, see [18], [48], [51], [54], [55].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In 2020, Nedoma et al performed cardiac triggering using the FBG sensor prototype with PDMS (polydimethylsiloxane polymer) encapsulation and in this time placed on the chest [70]. In this study, the optimal sensor placement was investigated first in laboratory conditions to generate greater BCG signal amplitude and it was found to be dependent on the size of the contact area of the sensor with the patient's body.…”
Section: Cardiac Monitoringmentioning
confidence: 98%
“…PMMA [74] or FBG [37]), sensors within harness (s2 -FBG, s3 -macro-bending [77]), chest sensor (s4 -e.g. FBG encapsulated in PDMS [70] or fiberglass [78]), pad sensor (s5, e.g. micro-bending pad [79] or FBG springboard [68]).…”
Section: Interrogation Unitmentioning
confidence: 99%