2017
DOI: 10.1016/j.talanta.2016.10.041
|View full text |Cite
|
Sign up to set email alerts
|

A novel, fast responding, low noise potentiometric sensor containing a carbon-based polymeric membrane for measuring surfactants in industrial and environmental applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…At all the selectivity measurements, DS was used as the analyte, in the range from 2 · 10 −6 M to 2 · 10 −3 M, whereas the concentration of the interfering ion was 0.01 M. DDA-TPB + 10 % C [5] DDA-TPB + graphene [19] L 1 [22] PPy-DBS [23] Interference The new FCNSS exhibited excellent selectivity for DS over all of the anions investigated. Comparing with other potentiometric surfactant sensors, FCNSS revealed superior selectivity performances.…”
Section: Determination Of the Potentiometric Selectivity Coefficientsmentioning
confidence: 99%
See 1 more Smart Citation
“…At all the selectivity measurements, DS was used as the analyte, in the range from 2 · 10 −6 M to 2 · 10 −3 M, whereas the concentration of the interfering ion was 0.01 M. DDA-TPB + 10 % C [5] DDA-TPB + graphene [19] L 1 [22] PPy-DBS [23] Interference The new FCNSS exhibited excellent selectivity for DS over all of the anions investigated. Comparing with other potentiometric surfactant sensors, FCNSS revealed superior selectivity performances.…”
Section: Determination Of the Potentiometric Selectivity Coefficientsmentioning
confidence: 99%
“…The standard methods for their determination are the methylene blue active substances method (MBAS) and the two-phase titration. [2,3] Due to many disadvantages of the standard methods, ASs are usually determined using other analytical approaches (potentiometric titration, [4,5] chromatography, [6,7] flow-injection analysis, [8,9] spectrophotometry, [10,11] biosensors, [12,13] etc.). Ion-selective electrodes (ISEs) as sensors in potentiometric titrations represent simple, cheap and rapid alternative to the standard methods.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, many toxic organic solvents such as chloroform are often used in the methods. Considering the above, there is a need for a simpler method based on chemical sensors such as ion selective electrodes (ISEs), [9][10][11][12][13][14][15][16] optical sensors (optodes) [17][18][19][20][21][22][23][24][25][26][27][28] and fiber optic sensors 29,30 to measure ASs without the use of toxic organic solvents.…”
Section: Introductionmentioning
confidence: 99%