2020
DOI: 10.1109/temc.2020.2999651
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Emission Test Method for Multiple Monopole Source Stirred Reverberation Chambers

Abstract: The terms and conditions for the reuse of this version of the manuscript are specified in the publishing policy. The use of copyrighted works requires the consent of the rights' holder (author or publisher). Works made available under a Creative Commons license or a Publisher's custom-made license can be used according to the terms and conditions contained therein. See editor's website for further information and terms and conditions. This item was downloaded from IRIS Università Politecnica delle Marche (http… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 11 publications
0
1
0
Order By: Relevance
“…Unlike SAC, EMC chambers that use two stirrers have a wider measurement space because they do not attach an absorber to the wall and do not require periodic maintenance of the absorber. However, EMC chamber's stirrer is also a bulky facility, so it occupies a certain space in EMC chamber [7], [8], and the maintenance cost of the step motor required to rotate the stirrer is also considerable [9], [10]. This paper proposes schroeder-type quadratic residue diffuser instead of EMC chamber stirrer to solve these problems as shown in Figure 3.…”
Section: Emc Chambermentioning
confidence: 99%
“…Unlike SAC, EMC chambers that use two stirrers have a wider measurement space because they do not attach an absorber to the wall and do not require periodic maintenance of the absorber. However, EMC chamber's stirrer is also a bulky facility, so it occupies a certain space in EMC chamber [7], [8], and the maintenance cost of the step motor required to rotate the stirrer is also considerable [9], [10]. This paper proposes schroeder-type quadratic residue diffuser instead of EMC chamber stirrer to solve these problems as shown in Figure 3.…”
Section: Emc Chambermentioning
confidence: 99%
“… volumetric, choosing the equivalent sources corresponding the EUT's volume, with a grid of 280 points; superficial, choosing only the subset of the equivalent sources corresponding to the EUT's external surface [28]. In this case, the number of the grid points is 112; ‘ad hoc’, choosing only the subset of the equivalent sources corresponding to the slot.…”
Section: Use Of a Subset Of Equivalent Sourcesmentioning
confidence: 99%