A novel embedded method for in-situ measuring internal multi-point temperatures of lithium ion batteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 66 publications
(42 citation statements)
references
References 26 publications
0
25
0
Order By: Relevance
“…Thereby, the used materials as well as the processing methods need to be considered for reliable and reproducible long term operation. Several studies use polyimide materials as support material or protective coating due to its very good thermal conductivity and chemical stability in polar aprotic solvents [333][334][335].…”
Section: Temperaturementioning
confidence: 99%
“…Thereby, the used materials as well as the processing methods need to be considered for reliable and reproducible long term operation. Several studies use polyimide materials as support material or protective coating due to its very good thermal conductivity and chemical stability in polar aprotic solvents [333][334][335].…”
Section: Temperaturementioning
confidence: 99%
“…Temperature inhomogeneities inside a battery can be measured with an instrumented cell with in situ measurement techniques during operation. [ 11–13 ] They can be induced by the inhomogeneous inner heat transfer paths and the anisotropic properties, caused by the layered structure of the electrode stacks, [ 14,15 ] with their typical combination of materials with high and low heat conductivity. [ 16 ] Furthermore, external conditions, such as the cooling system, can cause temperature inhomogeneities on the surface and within the cell.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, the BATTERY 2030 + proposed the smart batteries concept, which is based on newly embedded sensors for monitoring status changes in real time. Currently, the temperature of the LIBs has been measured by using different methods, such as thermocouple [13][14][15][16], thermo-resistive [17][18][19][20][21], infrared camera [22][23][24][25][26][27], and optical fibre [28][29][30][31][32]. It is a critical challenge to obtain internal measurement that harsh electrochemical environment, the particular packaging structures and the excellent performance of the LIBs.…”
Section: Introductionmentioning
confidence: 99%
“…Only a few methods have been applied to measure internal temperature of the pouch and cylindrical cells [16-18, 31, 32]. For the thermocouple [16] and thermo-resistive [17,18], the soft thin-film sensors with good chemical and thermal stability were preferred for avoiding physical damage to the electrodes and separators. The optical fibre was used to measure the internal temperature of 18,650 battery that placed in the centre of jelly roll [31,32].…”
Section: Introductionmentioning
confidence: 99%