2019
DOI: 10.1016/j.talanta.2018.12.039
|View full text |Cite
|
Sign up to set email alerts
|

A novel dual-color total internal reflection fluorescence detecting platform using compact optical structure and silicon-based photodetector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…The simultaneous detections of aflatoxin M1 (AFM1) and ochratoxin A (OTA) [ 54 ], Escherichia coli ( E. coli ) O157:H7 and Salmonella typhimurium [ 55 ], or acetamiprid and fipronil [ 56 ] were respectively achieved. The group further simplified the optical structure, where a single-multi mode fiber optic coupler was employed to replace the sophisticated confocal optical system for the transmission of two excitation lights and dual-color fluorescence [ 57 , 58 ]. A photodiode detector was used instead of a photomultiplier for the simultaneous detection of dual-color fluorescence.…”
Section: The Major Components Of Fluorescent Foew Sensors and Optical...mentioning
confidence: 99%
“…The simultaneous detections of aflatoxin M1 (AFM1) and ochratoxin A (OTA) [ 54 ], Escherichia coli ( E. coli ) O157:H7 and Salmonella typhimurium [ 55 ], or acetamiprid and fipronil [ 56 ] were respectively achieved. The group further simplified the optical structure, where a single-multi mode fiber optic coupler was employed to replace the sophisticated confocal optical system for the transmission of two excitation lights and dual-color fluorescence [ 57 , 58 ]. A photodiode detector was used instead of a photomultiplier for the simultaneous detection of dual-color fluorescence.…”
Section: The Major Components Of Fluorescent Foew Sensors and Optical...mentioning
confidence: 99%
“…A neoteric approach for sensitivity enhancement employed by Akhtar's group includes growing ZnO nanoflowers on a glass slide coated with silver nanofilm for ultrasensitive detection of insulin amyloid [178]. Sophisticated assemblies such as dual-colour TIR fluorescence detecting platform [179] as well as optical fibre-polymer waveguide-optical fibre sandwich [180] set up have facilitated small-molecule detection down to picomolar levels.…”
Section: Evanescent Wave-based Sensors For Biomedical Diagnosticsmentioning
confidence: 99%
“…Micromachines 2020, 11, x FOR PEER REVIEW 13 of 31 fluorescence detecting platform [179] as well as optical fibre-polymer waveguide-optical fibre sandwich [180] set up have facilitated small-molecule detection down to picomolar levels.…”
Section: Bioluminescence-based Sensors For Biomedical Diagnosticsmentioning
confidence: 99%
“…Our group recently developed a portable platform (i.e., the evanescent wave optofluidic immunosensing platform, OIP) that combines the advantages of evanescent wave fluorescence, microfluidics, and immunoassay [ 17 ]. Compared with other evanescent wave fluorescence biosensors (e.g., RAPTOR [ 18 ] and Analyte 2000 [ 19 ]), the OIP had a simpler and more compact optical structure, in which no rigorous optical alignment was required. The OIP possesses great potential for detecting various pollutants because of its several unique characteristics including low reagent consumption, rapidity, reproducibility, and portability, which are also the desired characteristics for on-site detection of food pollutants.…”
Section: Introductionmentioning
confidence: 99%
“…The hapten-carrier protein conjugates were covalently immobilized onto the bio-probe surface as biorecognition molecules using N,N′-disuccinimidyl carbonate (DSC) as the bifunctional reagent instead of other bifunctional reagents (e.g., glutaraldehyde). Second, a low-cost, Si-based photodiode detector (SOP-1000) with small volume and high sensitivity was used as an alternative to a photomultiplier tube (PMT) or lock-in amplifier for the detection of a weak fluorescence signal [ 18 ]. This not only reduced the cost instrument, but it also allowed for improved portability due to its small size.…”
Section: Introductionmentioning
confidence: 99%