A novel coplanar probe design for fast scanning of edema in human brain tissue via dielectric measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 19 publications
0
7
0
2
Order By: Relevance
“…Figure 9a-c shows the coplanar device used for brain tissue, the basic schematic of the device, and the base of the actual probe, respectively. [82] The effective permittivity is determined by measuring the phase shift of the transmitted electromagnetic wave, which then enables the determination of the water content and thus the extent of edema. Figure 9d shows the plot of permittivity against brain water content.…”
Section: Coplanar Probe (Copp)mentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 9a-c shows the coplanar device used for brain tissue, the basic schematic of the device, and the base of the actual probe, respectively. [82] The effective permittivity is determined by measuring the phase shift of the transmitted electromagnetic wave, which then enables the determination of the water content and thus the extent of edema. Figure 9d shows the plot of permittivity against brain water content.…”
Section: Coplanar Probe (Copp)mentioning
confidence: 99%
“…However, the author acknowledges that the sensor could be implemented in vivo upon sterilization. [82]…”
Section: Coplanar Probe (Copp)mentioning
confidence: 99%
“…2(a). It was originally designed for complex permittivity measurements of tissue in the MHz regime in order to determine the water content [22]. Based on the successful employment of this sensing principle, it was subsequently transferred to cell growth monitoring at low frequencies.…”
Section: Introductionmentioning
confidence: 99%
“…Weiterhin können sie als Tastkopf ausgeführt werden, wodurch eine Probenpräparation entfällt und schnelle zerstörungsfreie Messungen ermöglicht werden. In [8]…”
Section: Introductionunclassified
“…Da Γ und z jeweils abhängig von der effektiven Permittivität sind, kann diese nach[10] nummerisch aus (1) bestimmt werden. Weitere Ausführungen zu den Besonderheiten bei der Bestimmung der effektiven Permittivität bei Verwendung des beschriebenen Tastkopfs finden sich in[8]. Im Allgemeinen ist der Realteil einer Permittivität ein Maß für die Polarisierbarkeit des Materials und der Imaginärteil ein Maß für die dielektrischen Verluste.…”