A novel control strategy of a distributed generator operating in seven modes for ancillary services under grid faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…This adjustment is made by calculating the quantities of the active and reactive powers necessary to inject or absorb it, respectively, in or from the electrical network. These exchanged powers are determined by the following expressions: lefttruePitalicinj=kfΔfsignΔfΔfitalicaccQitalicinj=kvΔVsignΔVΔVitalicacc. …”
Section: Power Management Strategymentioning
confidence: 99%
See 2 more Smart Citations
“…This adjustment is made by calculating the quantities of the active and reactive powers necessary to inject or absorb it, respectively, in or from the electrical network. These exchanged powers are determined by the following expressions: lefttruePitalicinj=kfΔfsignΔfΔfitalicaccQitalicinj=kvΔVsignΔVΔVitalicacc. …”
Section: Power Management Strategymentioning
confidence: 99%
“…Specific standards for the grid frequency and voltage variations 33 In the case of overproduction of wind generator "P g > P L + P inj " and SC maximum SOC "U sc ≥ U scmax " and battery bank maximum SOC "SOC bat ≥ SOC batmax ," the wind turbine operates in limited mode. It provides only the power demanded by loads and system services.…”
Section: Figure 8 Power Management Strategymentioning
confidence: 99%
See 1 more Smart Citation
“…The excess or lack of fundamental active power generated by the WF will be injected or absorbed into or from the grid, respectively. However, the uncontrollable exchange of active power between WF and electrical power system may disrupt the stability of electrical network frequency [6,26]. In fact, it can create derivation which can exceed the normalized frequency variations mentioned in standards.…”
Section: Nl Loads Currents Identification Systemmentioning
confidence: 99%
“…New concepts have been elaborated to enhance the visibility of RDG to participate in system services and guarantee a satisfactory operation of the future main grid. From these new concepts, particular interest focuses on the MG (micro-grid), which is defined as a local energy system containing various microsources, and loads, and it can operate either connected or disconnected from the main grid [6].…”
Section: Introductionmentioning
confidence: 99%